This page records 88 verified defects in the printed 2024 Ontario Building Code. We found them while building the extraction quality-assurance system for this site and verified each finding directly against the source PDF.

These are defects in the published source, not corrections issued by the Province of Ontario. Evidence crops are included so each finding can be reviewed in its printed context.

Missing explanatory note targets

40 entries

Printed references to explanatory notes that do not exist in Appendix A.

  1. OBC-ERR-001Volume 1 · PDF page 76

    Printed text

    Note A-1.1.1.1.(1)

    Surrounding context

    …(1) This Code applies to the construction, demolition, change of use and occupancy of buildings. (See Note A- 1.1.1.1.(1)). (2) This Code applies to both site-built and factory-constructed buildings. (See Note A-1.1.1.1.(2))…

    Assessment

    Volume 1 prints “Note A-1.1.1.1.(1)” on PDF page 76. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-1.1.1.1.(2) on PDF page 6. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-001: Note A-1.1.1.1.(1)
    Source evidence · Volume 1, PDF page 76
  2. OBC-ERR-002Volume 1 · PDF page 78

    Printed text

    Note A-9.1.1.1.(1) of Division B

    Surrounding context

    …(a) reserved, (b) Group C, residential occupancies other than buildings used for retirement homes, (See Note A-9.1.1.1.(1) of Division B)…

    Assessment

    Volume 1 prints “Note A-9.1.1.1.(1) of Division B” on PDF page 78. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Appendix A. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-002: Note A-9.1.1.1.(1) of Division B
    Source evidence · Volume 1, PDF page 78
  3. OBC-ERR-005Volume 1 · PDF page 100

    Printed text

    Note A-1.1.4.2.(1)

    Surrounding context

    …(c) individual stores and individual or complementary rooms for business and personal services occupancies. (See Note A-1.1.4.2.(1)) Supply duct means a duct for conveying air from a heating, ventilating or air-conditioning appliance to a space to be…

    Assessment

    Volume 1 prints “Note A-1.1.4.2.(1)” on PDF page 100. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-005: Note A-1.1.4.2.(1)
    Source evidence · Volume 1, PDF page 100
  4. OBC-ERR-006Volume 1 · PDF page 124

    Printed text

    Note A-1.1.3.1.(2)

    Surrounding context

    …(2) The outside winter design temperatures determined from MMAH Supplementary Standard SB-1, “Climatic and Seismic Data”, shall be those listed for the January 2.5% values. (See Note A-1.1.3.1.(2)) 1.1.3.2. Depth of Frost Penetration…

    Assessment

    Volume 1 prints “Note A-1.1.3.1.(2)” on PDF page 124. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading with this base number; the only base-number hit is unrelated supplementary- standard text. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-006: Note A-1.1.3.1.(2)
    Source evidence · Volume 1, PDF page 124
  5. OBC-ERR-010Volume 1 · PDF page 154

    Printed text

    Note A-1.3.2.1.(1)

    Surrounding context

    …1.3.2.1. Abbreviations of Proper Names (See Note A-1.3.2.1.(1)) (1) The abbreviations of proper names in this Code shall have the meanings assigned to them in Table 1.3.2.1.…

    Assessment

    Volume 1 prints “Note A-1.3.2.1.(1)” on PDF page 154. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the broader A-1.3.2.1. heading on PDF page 17. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-010: Note A-1.3.2.1.(1)
    Source evidence · Volume 1, PDF page 154
  6. OBC-ERR-012Volume 1 · PDF page 166

    Printed text

    Note A-2.2.1.15.

    Surrounding context

    …2.2.1.15. Electrical Wiring and Equipment (See Note A-2.2.1.15.) (1) Reserved.…

    Assessment

    Volume 1 prints “Note A-2.2.1.15.” on PDF page 166. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the narrower A-2.2.1.15.(2) heading on PDF page 22. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-012: Note A-2.2.1.15.
    Source evidence · Volume 1, PDF page 166
  7. OBC-ERR-014Volume 1 · PDF page 185

    Printed text

    Note A-3.1.2.3.(1)

    Surrounding context

    …(1) An arena-type building intended for occasional use for trade shows and similar exhibition purposes shall be classified as Group A, Division 3 occupancy. (See Note A-3.1.2.3.(1)) 4 Division B – Part 3…

    Assessment

    Volume 1 prints “Note A-3.1.2.3.(1)” on PDF page 185. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-014: Note A-3.1.2.3.(1)
    Source evidence · Volume 1, PDF page 185
  8. OBC-ERR-017Volume 1 · PDF page 422

    Printed text

    Note A-3.13.4.3.(3)

    Surrounding context

    …(v) is made of a slip-resistant material. (See Note A-3.13.4.3.(3) and (4)) (4) The deck area required to make a lateral transfer to the transfer wall shall…

    Assessment

    Volume 1 prints “Note A-3.13.4.3.(3)” on PDF page 422. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the base number occurs only as a non-Appendix provision in later supplementary material. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-017: Note A-3.13.4.3.(3)
    Source evidence · Volume 1, PDF page 422
  9. OBC-ERR-018Volume 1 · PDF page 422

    Printed text

    Note A-3.13.4.3.(3) and (4)

    Surrounding context

    …(v) is made of a slip-resistant material. (See Note A-3.13.4.3.(3) and (4)) (4) The deck area required to make a lateral transfer to the transfer wall shall…

    Assessment

    Volume 1 prints “Note A-3.13.4.3.(3) and (4)” on PDF page 422. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the base number occurs only as a non-Appendix provision in later supplementary material. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-018: Note A-3.13.4.3.(3) and (4)
    Source evidence · Volume 1, PDF page 422
  10. OBC-ERR-019Volume 1 · PDF page 422

    Printed text

    Note A-3.13.4.3.(3)

    Surrounding context

    …(d) have a slope less than 2% provided at the base of the transfer wall surface. (See Note A-3.13.4.3.(3) and (4)) (5) The deck area described in Clause (4)(c) shall be centred on…

    Assessment

    Volume 1 prints “Note A-3.13.4.3.(3)” on PDF page 422. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the base number occurs only as a non-Appendix provision in later supplementary material. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-019: Note A-3.13.4.3.(3)
    Source evidence · Volume 1, PDF page 422
  11. OBC-ERR-020Volume 1 · PDF page 422

    Printed text

    Note A-3.13.4.3.(3) and (4)

    Surrounding context

    …(d) have a slope less than 2% provided at the base of the transfer wall surface. (See Note A-3.13.4.3.(3) and (4)) (5) The deck area described in Clause (4)(c) shall be centred on…

    Assessment

    Volume 1 prints “Note A-3.13.4.3.(3) and (4)” on PDF page 422. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the base number occurs only as a non-Appendix provision in later supplementary material. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-020: Note A-3.13.4.3.(3) and (4)
    Source evidence · Volume 1, PDF page 422
  12. OBC-ERR-022Volume 1 · PDF page 276

    Printed text

    Note A-3.2.3.14.(1)

    Surrounding context

    …(b) less than 2 m above an opening in the exterior wall of the exit. (See Note A-3.2.3.14.(1)) (2) If an unenclosed exterior exit stair or ramp could be exposed to fire from an opening in the exterior wall of the…

    Assessment

    Volume 1 prints “Note A-3.2.3.14.(1)” on PDF page 276. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the broader A-3.2.3.14. heading on PDF page 41. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-022: Note A-3.2.3.14.(1)
    Source evidence · Volume 1, PDF page 276
  13. OBC-ERR-023Volume 1 · PDF page 277

    Printed text

    Note A-3.2.3.14.(1)

    Surrounding context

    …the case where the exterior walls are parallel and face each other, θ = 0). (See Note A-3.2.3.14.(1).) (2) The exterior wall of each fire compartment referred to in Sentence (1) within the distance, D , shall have a fire-…

    Assessment

    Volume 1 prints “Note A-3.2.3.14.(1)” on PDF page 277. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the broader A-3.2.3.14. heading on PDF page 41. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-023: Note A-3.2.3.14.(1)
    Source evidence · Volume 1, PDF page 277
  14. OBC-ERR-024Volume 1 · PDF page 273

    Printed text

    Note A-3.3.4.6.(2)

    Surrounding context

    …the face of roof soffits above the exposing building face shall not project to less than 0.45 m from the property line. (See Note A-3.3.4.6.(2)) (4) The face of a roof soffit is permitted to project to the property line, where it faces a public way. (See Note A-…

    Assessment

    Volume 1 prints “Note A-3.3.4.6.(2)” on PDF page 273. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-024: Note A-3.3.4.6.(2)
    Source evidence · Volume 1, PDF page 273
  15. OBC-ERR-025Volume 1 · PDF page 273

    Printed text

    Note A-9.10.14.5.(11)

    Surrounding context

    …(4) The face of a roof soffit is permitted to project to the property line, where it faces a public way. (See Note A- 9.10.14.5.(11) and 9.10.15.5.(10)) (5) Where roof soffits project to less than 1.2 m from the centre line of a public way, or from an imaginary line between…

    Assessment

    Volume 1 prints “Note A-9.10.14.5.(11)” on PDF page 273. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-9.10.14.5.(1) on PDF page 205. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-025: Note A-9.10.14.5.(11)
    Source evidence · Volume 1, PDF page 273
  16. OBC-ERR-026Volume 1 · PDF page 273

    Printed text

    Note A-9.10.14.5.(11) and 9.10.15.5.(10)

    Surrounding context

    …(4) The face of a roof soffit is permitted to project to the property line, where it faces a public way. (See Note A- 9.10.14.5.(11) and 9.10.15.5.(10)) (5) Where roof soffits project to less than 1.2 m from the centre line of a public way, or from an imaginary line between…

    Assessment

    Volume 1 prints “Note A-9.10.14.5.(11) and 9.10.15.5.(10)” on PDF page 273. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading with this identifier. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-026: Note A-9.10.14.5.(11) and 9.10.15.5.(10)
    Source evidence · Volume 1, PDF page 273
  17. OBC-ERR-029Volume 1 · PDF page 297

    Printed text

    Note A-3.2.6.3.(1)

    Surrounding context

    …(1) If a building described in Article 3.2.6.1. is connected to any other building, measures shall be taken to limit movement of contaminated air from one building into another during a fire. (See Note A-3.2.6.3.(1)) 116 Division B – Part 3…

    Assessment

    Volume 1 prints “Note A-3.2.6.3.(1)” on PDF page 297. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the bracketed [3.2.6.3.(1)] on PDF page 687 belongs to MMAH Supplementary Standard SB-4. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-029: Note A-3.2.6.3.(1)
    Source evidence · Volume 1, PDF page 297
  18. OBC-ERR-034Volume 1 · PDF page 393

    Printed text

    Note A-3.8.3.3.(1)(b)

    Surrounding context

    …(a) have a minimum width not less than 1 000 mm between handrails, (See Note A-3.4.3.4.) (b) have a maximum gradient of 1 in 12, (See Note A-3.8.3.3.(1)(b)) (c) have a level area of at least 1 700 mm by 1 700 mm at the top and bottom of a ramp and where a door is located in a…

    Assessment

    Volume 1 prints “Note A-3.8.3.3.(1)(b)” on PDF page 393. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the broader A-3.8.3.3.(1) heading on PDF page 83. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-034: Note A-3.8.3.3.(1)(b)
    Source evidence · Volume 1, PDF page 393
  19. OBC-ERR-035Volume 1 · PDF page 528

    Printed text

    Note A-4.1.8.18.(13) and 4.4.3.1.(1)

    Surrounding context

    …analysis, provided the design achieves the minimum performance level required by Subsection 4.1.8. (See Note A- 4.1.8.18.(13) and 4.4.3.1.(1).) Division B – Part 4 79…

    Assessment

    Volume 1 prints “Note A-4.1.8.18.(13) and 4.4.3.1.(1)” on PDF page 528. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-035: Note A-4.1.8.18.(13) and 4.4.3.1.(1)
    Source evidence · Volume 1, PDF page 528
  20. OBC-ERR-036Volume 1 · PDF page 535

    Printed text

    Note A-4.2.2.3.(1)

    Surrounding context

    …subsurface conditions are consistent with the design and that construction is carried out in accordance with the design and good engineering practice. (See Note A-4.2.2.3.(1)) (2) The review required by Sentence (1) shall be carried out…

    Assessment

    Volume 1 prints “Note A-4.2.2.3.(1)” on PDF page 535. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the base number appears only as a non-Appendix provision in later supplementary material. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-036: Note A-4.2.2.3.(1)
    Source evidence · Volume 1, PDF page 535
  21. OBC-ERR-046Volume 1 · PDF page 599

    Printed text

    Note A-7.2.3.1.(1)

    Surrounding context

    …(c) have a water seal that does not depend on the action of moving parts. (See Note A-7.2.3.1.(1) and (3)) (2) The trap seal depth on fixtures draining to an acid waste system shall be a minimum of 50 mm.…

    Assessment

    Volume 1 prints “Note A-7.2.3.1.(1)” on PDF page 599. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-7.2.3.1.(3) on PDF page 157. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-046: Note A-7.2.3.1.(1)
    Source evidence · Volume 1, PDF page 599
  22. OBC-ERR-047Volume 1 · PDF page 599

    Printed text

    Note A-7.2.3.1.(1)

    Surrounding context

    …(b) be designed so that part of the trap can be removed for cleaning purposes. (See Note A-7.2.3.1.(1) and (3)) (4) A bell trap shall not be installed in a drainage system.…

    Assessment

    Volume 1 prints “Note A-7.2.3.1.(1)” on PDF page 599. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-7.2.3.1.(3) on PDF page 157. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-047: Note A-7.2.3.1.(1)
    Source evidence · Volume 1, PDF page 599
  23. OBC-ERR-049Volume 1 · PDF page 620

    Printed text

    Note A-7.2.3.1.(1)

    Surrounding context

    …7.3.3.4. Unions and Slip Joints (See Note A-7.2.3.1.(1) and (3)) (1) Except as provided in Sentence 7.4.6.3.(6), running thread and packing nut connections and unions with a gasket…

    Assessment

    Volume 1 prints “Note A-7.2.3.1.(1)” on PDF page 620. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-7.2.3.1.(3) on PDF page 157. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-049: Note A-7.2.3.1.(1)
    Source evidence · Volume 1, PDF page 620
  24. OBC-ERR-051Volume 1 · PDF page 625

    Printed text

    Note A-7.3.5.3.(1)

    Surrounding context

    …(1) Where piping may be exposed to freezing conditions, it shall be protected from the effects of freezing. (See Note A- 7.3.5.3.(1)) 7.3.5.4. Protection from Mechanical Damage…

    Assessment

    Volume 1 prints “Note A-7.3.5.3.(1)” on PDF page 625. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading; the base number appears only as a non-Appendix provision in later supplementary material. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-051: Note A-7.3.5.3.(1)
    Source evidence · Volume 1, PDF page 625
  25. OBC-ERR-052Volume 1 · PDF page 637

    Printed text

    Note A-7.4.9.3.

    Surrounding context

    …(2) The part of the fixture outlet pipe that is common to 3 compartments of a sink shall be one NPS larger than the largest fixture outlet pipe of the compartments that it serves. (See Note A-7.4.9.3.(2)) (3) Where clothes washers do not drain to a laundry tray, the trap inlet shall be not less than NPS 2 and be fitted with a…

    Assessment

    Volume 1 prints “Note A-7.4.9.3.” on PDF page 637. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints A-Table 7.4.9.3. and the narrower A-7.4.9.3.(2) on PDF page 165, but no broad Note heading. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-052: Note A-7.4.9.3.
    Source evidence · Volume 1, PDF page 637
  26. OBC-ERR-054Volume 1 · PDF page 649

    Printed text

    Note A-7.5.6.2.

    Surrounding context

    …7.5.6.2. Vent Pipe Connections (See Note A-7.5.6.2.) (1) Vent pipes in a plumbing system shall be installed so as to be direct as possible to a vent stack or open air, as the…

    Assessment

    Volume 1 prints “Note A-7.5.6.2.” on PDF page 649. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the narrower A-7.5.6.2.(2) heading on PDF page 166. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-054: Note A-7.5.6.2.
    Source evidence · Volume 1, PDF page 649
  27. OBC-ERR-059Volume 1 · PDF page 698

    Printed text

    Note A-8.7.7.1.(9)

    Surrounding context

    …(9) Where a stone layer is used, the effluent shall be evenly distributed within the stone layer to within 600 mm of the perimeter of the stone layer. (See Note A-8.7.7.1.(9)) (10) Where leaching chambers are used, the effluent shall be evenly distributed within the area over which the leaching…

    Assessment

    Volume 1 prints “Note A-8.7.7.1.(9)” on PDF page 698. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-8.7.7.1.(5) and (8) headings on PDF page 177. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-059: Note A-8.7.7.1.(9)
    Source evidence · Volume 1, PDF page 698
  28. OBC-ERR-061Volume 1 · PDF page 775

    Printed text

    Note A-3.2.3.4.(1)

    Surrounding context

    …(1) Except as provided in Articles 9.10.11.2., a party wall on a property line shall be constructed as a firewall. (See Note A-3.2.3.4.(1)) 9.10.11.2. Firewalls Not Required…

    Assessment

    Volume 1 prints “Note A-3.2.3.4.(1)” on PDF page 775. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-061: Note A-3.2.3.4.(1)
    Source evidence · Volume 1, PDF page 775
  29. OBC-ERR-065Volume 1 · PDF page 794

    Printed text

    Note A-3.2.4.20.(9)(a)

    Surrounding context

    …shall (a) be installed with permanent connections to an electrical circuit, (See Note A-3.2.4.20.(9)(a)) (b) have no disconnect switch between the overcurrent device and the smoke alarm, and…

    Assessment

    Volume 1 prints “Note A-3.2.4.20.(9)(a)” on PDF page 794. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints A-3.2.4.20.(9) on PDF page 48, but no clause-specific (9)(a) heading. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-065: Note A-3.2.4.20.(9)(a)
    Source evidence · Volume 1, PDF page 794
  30. OBC-ERR-070Volume 1 · PDF page 893

    Printed text

    Note A-9.1.1.1.(1)

    Surrounding context

    …be provided with sufficient thermal insulation to prevent moisture condensation on their room side during the winter and to ensure comfortable conditions for the occupants. (See Note A-9.1.1.1.(1)) 9.25.2.2. Insulation Materials…

    Assessment

    Volume 1 prints “Note A-9.1.1.1.(1)” on PDF page 893. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Appendix A. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-070: Note A-9.1.1.1.(1)
    Source evidence · Volume 1, PDF page 893
  31. OBC-ERR-072Volume 1 · PDF page 923

    Printed text

    Note A-9.27.9.2.(2)

    Surrounding context

    …(2) Where hardboard cladding is grooved, the grooves shall not extend more than1.5 mm into the minimum required thickness. (See Note A-9.27.9.2.(2)) 9.27.9.3. Panel Cladding…

    Assessment

    Volume 1 prints “Note A-9.27.9.2.(2)” on PDF page 923. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only A-9.27.9.2.(3) on PDF page 268. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-072: Note A-9.27.9.2.(2)
    Source evidence · Volume 1, PDF page 923
  32. OBC-ERR-073Volume 1 · PDF page 715

    Printed text

    Note A-9.4.2.1.

    Surrounding context

    …9.4.2.1. Application (See Note A-9.4.2.1. and 9.4.2.2.) (1) This Subsection applies to light-frame construction whose wall, floor and roof planes are generally comprised of…

    Assessment

    Volume 1 prints “Note A-9.4.2.1.” on PDF page 715. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the narrower compound A-9.4.2.1.(1) and 9.4.2.2. on PDF page 185. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-073: Note A-9.4.2.1.
    Source evidence · Volume 1, PDF page 715
  33. OBC-ERR-074Volume 1 · PDF page 715

    Printed text

    Note A-9.4.2.1.

    Surrounding context

    …9.4.2.2. Specified Snow Loads (See Note A-9.4.2.1. and 9.4.2.2.) (1) Except as provided in Sentences (2) and (4), specified snow loads shall be not less than those calculated using the…

    Assessment

    Volume 1 prints “Note A-9.4.2.1.” on PDF page 715. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found Volume 2 prints only the narrower compound A-9.4.2.1.(1) and 9.4.2.2. on PDF page 185. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-074: Note A-9.4.2.1.
    Source evidence · Volume 1, PDF page 715
  34. OBC-ERR-075Volume 1 · PDF page 719

    Printed text

    Note A-9.5.2.4.(1)

    Surrounding context

    …(c) for a bathtub, a grab bar described in Clause 3.8.3.13.(7)(e). (See Note A-9.5.2.4.(1)) 16 Division B – Part 9…

    Assessment

    Volume 1 prints “Note A-9.5.2.4.(1)” on PDF page 719. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-075: Note A-9.5.2.4.(1)
    Source evidence · Volume 1, PDF page 719
  35. OBC-ERR-078Volume 1 · PDF page 744

    Printed text

    Note A-9.8.3.3.

    Surrounding context

    …9.8.8.3. Height of Guards (See Note A-9.8.3.3.) (1) Except as provided in Sentences (2) to (3.1), all guards shall be not less than 1 070 mm high.…

    Assessment

    Volume 1 prints “Note A-9.8.3.3.” on PDF page 744. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no Appendix A heading with this identifier. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-078: Note A-9.8.3.3.
    Source evidence · Volume 1, PDF page 744
  36. OBC-ERR-083Volume 1 · PDF page 544

    Printed text

    Note A-4.1.8.18.(13) and 4.4.3.1.(1)

    Surrounding context

    …(1) Storage racks, including anchorage of racks, shall be designed for loads in accordance with this Part. (See Note A-4.1.8.18.(13) and 4.4.3.1.(1).)…

    Assessment

    Volume 1 prints “Note A-4.1.8.18.(13) and 4.4.3.1.(1)” on PDF page 544. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found no occurrence of the base number in Volume 2. The cited scope therefore has no matching explanatory-note heading; silently linking it to a broader or narrower note would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-083: Note A-4.1.8.18.(13) and 4.4.3.1.(1)
    Source evidence · Volume 1, PDF page 544
  37. OBC-ERR-085Volume 1 · PDF page 827

    Printed text

    Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)

    Surrounding context

    …(3) The perimeter of the ground cover required in Sentence (1) shall be sealed to the foundation wall. (See Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3))…

    Assessment

    Volume 1 prints “Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)” on PDF page 827, while Article 9.25.3.4. is marked Reserved on PDF page 896. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found the base number only in prose on PDF page 227 and no matching explanatory-note heading. Silently linking it elsewhere would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-085: Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)
    Source evidence · Volume 1, PDF page 827
  38. OBC-ERR-086Volume 1 · PDF page 827

    Printed text

    Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)

    Surrounding context

    …(3) The perimeter of the ground cover required in Sentence (1) shall be sealed to the foundation wall. (See Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3))…

    Assessment

    Volume 1 prints “Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)” on PDF page 827, while Article 9.25.3.6. is marked Reserved on PDF page 896. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found the base number only in prose on PDF page 227 and no matching explanatory-note heading. Silently linking it elsewhere would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-086: Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)
    Source evidence · Volume 1, PDF page 827
  39. OBC-ERR-087Volume 1 · PDF page 827

    Printed text

    Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)

    Surrounding context

    …(3) The perimeter of the ground cover required in Sentence (1) shall be sealed to the foundation wall. (See Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3))…

    Assessment

    Volume 1 prints “Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)” on PDF page 827, while Article 9.25.3.6. is marked Reserved and has no Sentence (2) on PDF page 896. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found the identifier only in prose on PDF page 227 and no matching explanatory-note heading. Silently linking it elsewhere would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-087: Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)
    Source evidence · Volume 1, PDF page 827
  40. OBC-ERR-088Volume 1 · PDF page 827

    Printed text

    Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)

    Surrounding context

    …(3) The perimeter of the ground cover required in Sentence (1) shall be sealed to the foundation wall. (See Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3))…

    Assessment

    Volume 1 prints “Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)” on PDF page 827, while Article 9.25.3.6. is marked Reserved and has no Sentence (3) on PDF page 896. A page-by-page search of all 997 pages of Volume 2, including A-, A. and unprefixed spellings and compound headings, found the identifier only in prose on PDF page 227 and no matching explanatory-note heading. Silently linking it elsewhere would change the printed reference.

    View the article on this site
    Evidence crop for OBC-ERR-088: Notes A-9.13.4., A-9.25.3.4. and 9.25.3.6., and A-9.25.3.6.(2) and (3)
    Source evidence · Volume 1, PDF page 827

Stale reference targets

29 entries

Printed references to provisions that do not exist in the 2024 Code.

  1. OBC-ERR-003Volume 1 · PDF page 80

    Printed text

    7.1.1A.1.(1)

    Surrounding context

    …(i) Sentences 1.4.1.3.(1) and (2) of Division A, and (ii) Sentences 3.13.1.2.(1), 7.1.1A.1.(1), 8.1.1.2.(1) and 11.1.1.2.(1) of Division B, or (c) the following meaning for the purposes of this Code:…

    Assessment

    Volume 1 prints “7.1.1A.1.(1)” on PDF page 80. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Division B contains no Article 7.1.1A.1. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-003: 7.1.1A.1.(1)
    Source evidence · Volume 1, PDF page 80
  2. OBC-ERR-004Volume 1 · PDF page 80

    Printed text

    8.1.1.2.(1)

    Surrounding context

    …(i) Sentences 1.4.1.3.(1) and (2) of Division A, and (ii) Sentences 3.13.1.2.(1), 7.1.1A.1.(1), 8.1.1.2.(1) and 11.1.1.2.(1) of Division B, or (c) the following meaning for the purposes of this Code:…

    Assessment

    Volume 1 prints “8.1.1.2.(1)” on PDF page 80. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Division B contains no Article 8.1.1.2. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-004: 8.1.1.2.(1)
    Source evidence · Volume 1, PDF page 80
  3. OBC-ERR-007Volume 1 · PDF page 132

    Printed text

    Table 9.27.2.1.-B

    Surrounding context

    …Non-Fibered, Asbestos-Fibered, and Non-Asbestos-Fibered Table 9.27.2.1.-B Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic…

    Assessment

    Volume 1 prints “Table 9.27.2.1.-B” on PDF page 132. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 9.27.2.1. has no table with a -B identifier. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-007: Table 9.27.2.1.-B
    Source evidence · Volume 1, PDF page 132
  4. OBC-ERR-008Volume 1 · PDF page 153

    Printed text

    Table 9.23.17.1.-A

    Surrounding context

    …Table 5.9.1.1. Table 9.23.17.1.-A ULC CAN/ULC-S701.1:2017 Standard for Thermal Insulation, Polystyrene Boards…

    Assessment

    Volume 1 prints “Table 9.23.17.1.-A” on PDF page 153. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 9.23.17.1. has no table; the lettered wall-sheathing tables occur under Article 9.23.17.2. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-008: Table 9.23.17.1.-A
    Source evidence · Volume 1, PDF page 153
  5. OBC-ERR-009Volume 1 · PDF page 131

    Printed text

    Table 9.23.17.2.

    Surrounding context

    …Table 5.9.1.1. Table 9.23.17.2.-A 9.29.5.2.(1)…

    Assessment

    Volume 1 prints “Table 9.23.17.2.” on PDF page 131. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; the PDF prints Article 9.23.17.2. and Tables 9.23.17.2.-A and -B, but no unlettered Table 9.23.17.2. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-009: Table 9.23.17.2.
    Source evidence · Volume 1, PDF page 131
  6. OBC-ERR-015Volume 1 · PDF page 418

    Printed text

    Sentence 3.1.17.3.(1)

    Surrounding context

    …3.7.4.3.-C for an occupant load based on (a) the formula in Sentence 3.1.17.3.(1) for all public pools, except a wave action pool, or (b) the formula in Sentence 3.1.17.3.(2) for a wave action pool.…

    Assessment

    Volume 1 prints “Sentence 3.1.17.3.(1)” on PDF page 418. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; the hierarchy has no Article 3.1.17.3. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-015: Sentence 3.1.17.3.(1)
    Source evidence · Volume 1, PDF page 418
  7. OBC-ERR-016Volume 1 · PDF page 418

    Printed text

    Sentence 3.1.17.3.(2)

    Surrounding context

    …(a) the formula in Sentence 3.1.17.3.(1) for all public pools, except a wave action pool, or (b) the formula in Sentence 3.1.17.3.(2) for a wave action pool. (5) A minimum of one shower head shall be provided for every 40 bathers.…

    Assessment

    Volume 1 prints “Sentence 3.1.17.3.(2)” on PDF page 418. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; the hierarchy has no Article 3.1.17.3. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-016: Sentence 3.1.17.3.(2)
    Source evidence · Volume 1, PDF page 418
  8. OBC-ERR-021Volume 1 · PDF page 267

    Printed text

    Article 3.1.18.3.

    Surrounding context

    …(See Note A-3) (See also Article 3.1.18.3.) (2) The area of the unprotected openings in an exposing building face shall be the aggregate area of unprotected…

    Assessment

    Volume 1 prints “Article 3.1.18.3.” on PDF page 267. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; the hierarchy has no Article 3.1.18.3. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-021: Article 3.1.18.3.
    Source evidence · Volume 1, PDF page 267
  9. OBC-ERR-030Volume 1 · PDF page 313

    Printed text

    Sentence 3.8.3.6.(4)

    Surrounding context

    …(3) Except as permitted by Sentence (4), door release hardware shall be operable by one hand and the door shall be openable with not more than one releasing operation. (See also Sentence 3.8.3.6.(4)) (4) Except in a retirement home, an egress door from an individual dwelling unit or from a suite of residential…

    Assessment

    Volume 1 prints “Sentence 3.8.3.6.(4)” on PDF page 313. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 3.8.3.6. contains only Sentences (1) through (3). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-030: Sentence 3.8.3.6.(4)
    Source evidence · Volume 1, PDF page 313
  10. OBC-ERR-031Volume 1 · PDF page 321

    Printed text

    Sentence 3.3.2.3.(4)

    Surrounding context

    …distance shall be not more than 45 m measured from the most remote point of the aisle to an exit. (17) Side aisles shall be not less than 1 100 mm wide if seating is provided in conformance with Sentence 3.3.2.3.(4). (18) An aisle that has a slope not more than 1 in 8 shall not be stepped.…

    Assessment

    Volume 1 prints “Sentence 3.3.2.3.(4)” on PDF page 321. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 3.3.2.3. is printed as Reserved and has no Sentences. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-031: Sentence 3.3.2.3.(4)
    Source evidence · Volume 1, PDF page 321
  11. OBC-ERR-037Volume 1 · PDF page 544

    Printed text

    Article 1.1.2.2. of Division A

    Surrounding context

    …(1) Where suspended maintenance and window cleaning operations are intended to be carried out on the exterior of a building described in Article 1.1.2.2. of Division A, anchor systems shall be provided where any portion of the roof is more than 8 m above adjacent ground level.…

    Assessment

    Volume 1 prints “Article 1.1.2.2. of Division A” on PDF page 544. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Division A contains no Article 1.1.2.2.; the similarly numbered indexed occurrences are not a Division A target. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-037: Article 1.1.2.2. of Division A
    Source evidence · Volume 1, PDF page 544
  12. OBC-ERR-038Volume 1 · PDF page 579

    Printed text

    Sentence 6.2.1.2.(2)

    Surrounding context

    …6.3.2.14. Cleaning Devices (1) Where outdoor air quality conditions do not meet the requirements of Sentence 6.2.1.2.(2), ventilation required by Sentence 6.3.1.1.(1) shall be provided by a ventilation system designed to include devices that reduce particles and gases…

    Assessment

    Volume 1 prints “Sentence 6.2.1.2.(2)” on PDF page 579. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 6.2.1.2. contains only Sentence (1). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-038: Sentence 6.2.1.2.(2)
    Source evidence · Volume 1, PDF page 579
  13. OBC-ERR-039Volume 1 · PDF page 579

    Printed text

    Sentence 6.2.1.2.(2)

    Surrounding context

    …Sentence 6.3.1.1.(1) shall be provided by a ventilation system designed to include devices that reduce particles and gases to the maximum acceptable levels described in Sentence 6.2.1.2.(2) prior to the introduction of outdoor air to indoor occupied spaces.…

    Assessment

    Volume 1 prints “Sentence 6.2.1.2.(2)” on PDF page 579. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 6.2.1.2. contains only Sentence (1). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-039: Sentence 6.2.1.2.(2)
    Source evidence · Volume 1, PDF page 579
  14. OBC-ERR-040Volume 1 · PDF page 577

    Printed text

    6.2.1.2.(2)

    Surrounding context

    …(2) Outdoor air intakes shall be located so that (a) the quality of the air entering the building complies with Sentences 6.2.1.2.(2) and (3), and (b) they are separated a minimum distance from sources of contaminants in accordance with Table 6.3.2.9.…

    Assessment

    Volume 1 prints “6.2.1.2.(2)” on PDF page 577. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 6.2.1.2. contains only Sentence (1). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-040: 6.2.1.2.(2)
    Source evidence · Volume 1, PDF page 577
  15. OBC-ERR-041Volume 1 · PDF page 577

    Printed text

    Sentences 6.2.1.2.(2) and (3)

    Surrounding context

    …(2) Outdoor air intakes shall be located so that (a) the quality of the air entering the building complies with Sentences 6.2.1.2.(2) and (3), and (b) they are separated a minimum distance from sources of contaminants in accordance with Table 6.3.2.9.…

    Assessment

    Volume 1 prints “Sentences 6.2.1.2.(2) and (3)” on PDF page 577. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 6.2.1.2. contains only Sentence (1). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-041: Sentences 6.2.1.2.(2) and (3)
    Source evidence · Volume 1, PDF page 577
  16. OBC-ERR-043Volume 1 · PDF page 589

    Printed text

    6.9.4.3.

    Surrounding context

    …operated. (3) Except as permitted in Sentence (4), the carbon monoxide alarms required by Articles 6.9.4.2. and 6.9.4.3. shall have a visual signalling component conforming to the requirements in 18.5.3. (Light, Color and Pulse Characteristics) of…

    Assessment

    Volume 1 prints “6.9.4.3.” on PDF page 589. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Subsection 6.9.4. ends at Article 6.9.4.2. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-043: 6.9.4.3.
    Source evidence · Volume 1, PDF page 589
  17. OBC-ERR-044Volume 1 · PDF page 595

    Printed text

    Article 7.7.4.1.

    Surrounding context

    …main, drinking water system or a potable private water supply system. (2) Storm sewage or greywater that is free of solids and treated to conform to Article 7.7.4.1. is permitted to be used as a water supply for…

    Assessment

    Volume 1 prints “Article 7.7.4.1.” on PDF page 595. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Division B contains no Subsection 7.7.4. or Article 7.7.4.1. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-044: Article 7.7.4.1.
    Source evidence · Volume 1, PDF page 595
  18. OBC-ERR-045Volume 1 · PDF page 595

    Printed text

    Article 7.7.4.1.

    Surrounding context

    …(d) the priming of traps. (3) Rainwater that is free of solids and treated to conform to Article 7.7.4.1. is permitted to be used as a water supply for…

    Assessment

    Volume 1 prints “Article 7.7.4.1.” on PDF page 595. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Division B contains no Subsection 7.7.4. or Article 7.7.4.1. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-045: Article 7.7.4.1.
    Source evidence · Volume 1, PDF page 595
  19. OBC-ERR-060Volume 1 · PDF page 774

    Printed text

    9.33.1.2.(1)

    Surrounding context

    …room separated from the remainder of the building by a fire separation having not less than a 1 h fire-resistance rating. (2) Except as required in the appliance installation standards referenced in Sentences 6.2.1.5.(1) and 9.33.1.2.(1), fuel- fired space-heating appliances, space-cooling appliances and service water heaters need not be separated from the…

    Assessment

    Volume 1 prints “9.33.1.2.(1)” on PDF page 774. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Subsection 9.33.1. contains Article 9.33.1.1. only. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-060: 9.33.1.2.(1)
    Source evidence · Volume 1, PDF page 774
  20. OBC-ERR-066Volume 1 · PDF page 771

    Printed text

    Sentence 9.10.9.3.(2)

    Surrounding context

    …(b) the underside of floor-ceiling framing. (See Sentence 9.10.9.3.(2) for closures.) (5) The fire-resistance rating of the fire separation required in Sentence (4) is permitted to be waived where the house…

    Assessment

    Volume 1 prints “Sentence 9.10.9.3.(2)” on PDF page 771. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 9.10.9.3. contains only Sentence (1). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-066: Sentence 9.10.9.3.(2)
    Source evidence · Volume 1, PDF page 771
  21. OBC-ERR-067Volume 1 · PDF page 772

    Printed text

    Sentence 9.10.9.3.(2)

    Surrounding context

    …(b) the underside of floor-ceiling framing separating the corridor from the remainder of the building. (See Sentence 9.10.9.3.(2) for closures.) (5) No fire separation is required in a sprinklered floor area between a public corridor and a space containing plumbing…

    Assessment

    Volume 1 prints “Sentence 9.10.9.3.(2)” on PDF page 772. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 9.10.9.3. contains only Sentence (1). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-067: Sentence 9.10.9.3.(2)
    Source evidence · Volume 1, PDF page 772
  22. OBC-ERR-068Volume 1 · PDF page 849

    Printed text

    Article 9.33.1.2.

    Surrounding context

    …(1) Except for chimneys serving fireplaces, the size of a chimney flue shall conform to the requirements of the solid fuel- burning appliance installation standards referenced in Sentence 6.2.1.4.(1) and Article 9.33.1.2. (2) Where a chimney flue serves only one solid fuel-burning appliance, the flue area shall be at least equal to that of the…

    Assessment

    Volume 1 prints “Article 9.33.1.2.” on PDF page 849. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Subsection 9.33.1. contains Article 9.33.1.1. only. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-068: Article 9.33.1.2.
    Source evidence · Volume 1, PDF page 849
  23. OBC-ERR-069Volume 1 · PDF page 861

    Printed text

    Sentence 9.23.3.4.(3)

    Surrounding context

    …(2) See Sentence 9.23.3.4.(2). (3) See Sentence 9.23.3.4.(3). (4) See Sentence 9.23.13.5.(3).…

    Assessment

    Volume 1 prints “Sentence 9.23.3.4.(3)” on PDF page 861. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 9.23.3.4. contains Sentences (1) and (2) only, although Note (3) to its table still cites Sentence (3). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-069: Sentence 9.23.3.4.(3)
    Source evidence · Volume 1, PDF page 861
  24. OBC-ERR-076Volume 1 · PDF page 729

    Printed text

    Sentence 9.5.1.4.(1)

    Surrounding context

    …(3) Work areas in live/work units shall conform to Clause 3.7.2.1.(2)(a). (4) Where rooms with different requirements for window glass area are combined as described in Sentence 9.5.1.4.(1), the more restrictive requirement shall govern.…

    Assessment

    Volume 1 prints “Sentence 9.5.1.4.(1)” on PDF page 729. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Division B contains no Article 9.5.1.4. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-076: Sentence 9.5.1.4.(1)
    Source evidence · Volume 1, PDF page 729
  25. OBC-ERR-079Volume 1 · PDF page 753

    Printed text

    Sentence 3.8.3.6.(4)

    Surrounding context

    …and to garages serving a single dwelling unit, door release hardware on doors in a means of egress shall be operable with one hand and the door shall be openable with not more than one releasing operation. (See also Sentence 3.8.3.6.(4) and Note A-3.3.1.13.(4))…

    Assessment

    Volume 1 prints “Sentence 3.8.3.6.(4)” on PDF page 753. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 3.8.3.6. contains only Sentences (1) through (3). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-079: Sentence 3.8.3.6.(4)
    Source evidence · Volume 1, PDF page 753
  26. OBC-ERR-080Volume 1 · PDF page 754

    Printed text

    Sentence 3.8.3.6.(8)

    Surrounding context

    …with a secondary suite, shall be designed and installed so that when the latch is released the door will open in the direction of exit travel under a force of not more than 90 N applied to the door release hardware. (See Sentence 3.8.3.6.(8) for door opening forces in a barrier-free path of travel.)…

    Assessment

    Volume 1 prints “Sentence 3.8.3.6.(8)” on PDF page 754. A page-by-page search of all 1,251 Volume 1 pages found no matching target heading; Article 3.8.3.6. contains only Sentences (1) through (3). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-080: Sentence 3.8.3.6.(8)
    Source evidence · Volume 1, PDF page 754
  27. OBC-ERR-081Volume 1 · PDF page 313

    Printed text

    Sentence 3.8.3.6.(17)

    Surrounding context

    …3.3.1.13. Doors and Door Hardware (See also Sentence 3.8.3.6.(17)) (1) Except as required by Article 3.3.3.4. and Sentences 3.3.4.11.(11), 3.8.3.3.(1) and (2), a door that opens into or is located within a public corridor…

    Assessment

    Volume 1 prints “Sentence 3.8.3.6.(17)” on PDF page 313. A page-by-page search of all 1,251 Volume 1 pages found the identifier only in the citations on PDF pages 313 and 352; Article 3.8.3.6. contains only Sentences (1) through (3). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-081: Sentence 3.8.3.6.(17)
    Source evidence · Volume 1, PDF page 313
  28. OBC-ERR-082Volume 1 · PDF page 352

    Printed text

    Sentence 3.8.3.6.(17)

    Surrounding context

    …3.4.6.11. Doors (See also Sentence 3.8.3.6.(17)) (1) The distance between a stair riser and the leading edge of a door during its swing shall be not less than 300 mm.…

    Assessment

    Volume 1 prints “Sentence 3.8.3.6.(17)” on PDF page 352. A page-by-page search of all 1,251 Volume 1 pages found the identifier only in the citations on PDF pages 313 and 352; Article 3.8.3.6. contains only Sentences (1) through (3). The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-082: Sentence 3.8.3.6.(17)
    Source evidence · Volume 1, PDF page 352
  29. OBC-ERR-084Volume 1 · PDF page 613

    Printed text

    7.6.5.3.(1)

    Surrounding context

    …(4) Except as provided in Sentences (5) and (6) and 7.6.5.3.(1), the temperature of water discharging from a shower head or into a bathtub shall not exceed 49°C.…

    Assessment

    Volume 1 prints “7.6.5.3.(1)” on PDF page 613. A page-by-page search of all 1,251 Volume 1 pages found the identifier only in this citation; the base number also appears in the subject index, but Division B contains no Article 7.6.5.3. The citation is therefore stale or points to a provision omitted from this edition, rather than to an extraction anchor that actually exists in the PDF.

    View the article on this site
    Evidence crop for OBC-ERR-084: 7.6.5.3.(1)
    Source evidence · Volume 1, PDF page 613

Printed identifier typos

13 entries

Identifiers whose printed form conflicts with the target identifiable from context.

  1. OBC-ERR-011Volume 1 · PDF page 1031

    Printed text

    6.2.4.7.(1)

    Surrounding context

    …conform to the requirements of Subsection 3.2.6., Sections 3.7., 3.11. and 3.12., Sentences 6.3.1.1.(2), 6.3.2.7.(1) and 6.2.4.7.(1), Subsections 9.5.1. and 9.5.3., 9.5.3A. to 9.5.3F. and 9.5.4., Sentences 9.6.1.4.(3), (4), Article 9.7.2.3., Sentences 9.8.8.1.(4) to (8) and 9.9.10.1.(1) to (7), Subsection 9.10.17., Sections 9.31. and 9.32., and Subsections 9.34.1.…

    Assessment

    Volume 1 prints “6.2.4.7.(1)” on PDF page 1031 in a list otherwise citing Part 6 provisions under 6.3. A full-volume search found no Article 6.2.4.7. or Sentence (1), and Part 6 has no Subsection 6.2.4.; the only occurrence is this citation. The identifier is therefore misprinted or obsolete, but the intended replacement cannot be inferred safely from the 2024 text.

    View the article on this site
    Evidence crop for OBC-ERR-011: 6.2.4.7.(1)
    Source evidence · Volume 1, PDF page 1031
  2. OBC-ERR-027Volume 1 · PDF page 289

    Printed text

    Sentences 3.2.4.22.(17) to (19)

    Surrounding context

    …(a) capable of sounding audible signals in accordance with Sentences 3.2.4.20.(12) and (16), (b) provided with a visual signalling component in accordance with Sentences 3.2.4.22.(17) to (19), (c) powered in accordance with Sentence 3.2.4.20.(9), and…

    Assessment

    Volume 1 prints “Sentences 3.2.4.22.(17) to (19)” on PDF page 289. The exact kind-and- identifier combination has no matching target anywhere in the relevant PDF, while Sentence 3.2.4.20.(17) is printed on PDF page 289 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-027: Sentences 3.2.4.22.(17) to (19)
    Source evidence · Volume 1, PDF page 289
  3. OBC-ERR-028Volume 1 · PDF page 289

    Printed text

    Sentences 3.2.4.22.(17) to (19)

    Surrounding context

    …(a) capable of sounding audible signals in accordance with Sentences 3.2.4.20.(12) and (16), (b) provided with a visual signalling component in accordance with Sentences 3.2.4.22.(17) to (19), (c) powered in accordance with Sentence 3.2.4.20.(9), and…

    Assessment

    Volume 1 prints “Sentences 3.2.4.22.(17) to (19)” on PDF page 289. The exact kind-and- identifier combination has no matching target anywhere in the relevant PDF, while Sentence 3.2.4.20.(19) is printed on PDF page 289 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-028: Sentences 3.2.4.22.(17) to (19)
    Source evidence · Volume 1, PDF page 289
  4. OBC-ERR-032Volume 1 · PDF page 385

    Printed text

    Note A-3.8.2.1.(b)

    Surrounding context

    …(b) within all normally occupied floor areas and rooftop amenity spaces, unless as permitted by Sentence (2). (See Note A-3.8.2.1.(b)) (See Article 3.3.1.7. for additional requirements regarding floor areas above or below the first storey to which a barrier-free path of travel is required).…

    Assessment

    Volume 1 prints “Note A-3.8.2.1.(b)” on PDF page 385. Volume 2 has no A-3.8.2.1.(b) heading but visibly prints A-3.8.2.1.(1)(b) on PDF page 75; the omitted (1) is the sole difference and the Appendix text addresses the cited clause. This is a printed identifier omission, not a missing extraction target.

    View the article on this site
    Evidence crop for OBC-ERR-032: Note A-3.8.2.1.(b)
    Source evidence · Volume 1, PDF page 385
  5. OBC-ERR-042Volume 1 · PDF page 583

    Printed text

    6.2.4.4.

    Surrounding context

    …(1) A power-ventilated enclosure required by the Fire Code made under the Fire Protection and Prevention Act, 1997 shall be designed and constructed to conform to Articles 6.3.4.3. and 6.2.4.4. 6.3.4.3. Enclosure Exhaust Ventilation…

    Assessment

    Volume 1 prints “6.2.4.4.” on PDF page 583. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Article 6.3.4.4. is printed on PDF page 583 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-042: 6.2.4.4.
    Source evidence · Volume 1, PDF page 583
  6. OBC-ERR-048Volume 1 · PDF page 609

    Printed text

    Table 2.2.7.4.

    Surrounding context

    …(b) ASTM B306, “Standard Specification for Copper Drainage Tube (DWV).” (2) Except as provided in Sentence (3), the use of copper tube shall conform to Table 2.2.7.4. Table 7.2.7.4.…

    Assessment

    Volume 1 prints “Table 2.2.7.4.” on PDF page 609. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Table 7.2.7.4. is printed on PDF page 609 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-048: Table 2.2.7.4.
    Source evidence · Volume 1, PDF page 609
  7. OBC-ERR-050Volume 1 · PDF page 622

    Printed text

    Table 2.3.4.5.

    Surrounding context

    …the effects of thrust. (2) Nominally horizontal piping shall be supported as stated in Table 2.3.4.5. (3) Where PVC, CPVC or ABS plastic pipe is installed,…

    Assessment

    Volume 1 prints “Table 2.3.4.5.” on PDF page 622. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Table 7.3.4.5. is printed on PDF page 623 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-050: Table 2.3.4.5.
    Source evidence · Volume 1, PDF page 622
  8. OBC-ERR-053Volume 1 · PDF page 647

    Printed text

    7.10.4.8.

    Surrounding context

    …(9) A circuit-vented branch, including the fixture drain downstream of the circuit vent connection, shall be sized in accordance with Articles 7.4.10.7. and 7.10.4.8., except that it shall be not less than (a) NPS 2, where traps less than NPS 2 are circuit-vented, or…

    Assessment

    Volume 1 prints “7.10.4.8.” on PDF page 647. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Article 7.4.10.8. is printed on PDF page 643 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-053: 7.10.4.8.
    Source evidence · Volume 1, PDF page 647
  9. OBC-ERR-055Volume 1 · PDF page 660

    Printed text

    Article 2.6.3.3.

    Surrounding context

    …(b) backflow preventers required by Sentence 7.6.2.1.(3), and (c) pressure-reducing valves required by Article 2.6.3.3. (See Note A-7.6.1.11.(1))…

    Assessment

    Volume 1 prints “Article 2.6.3.3.” on PDF page 660. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Article 7.6.3.3. is printed on PDF page 667 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-055: Article 2.6.3.3.
    Source evidence · Volume 1, PDF page 660
  10. OBC-ERR-056Volume 1 · PDF page 658

    Printed text

    Table 7.6.41.6.-B

    Surrounding context

    …(4) In buildings classified as Group C occupancy, the flush cycle for each fixture that is a water closet or urinal shall not exceed the maximum water used in each flush cycle listed for that fixture in Table 7.6.41.6.-B. (4.1) Sentences (3) and (4) do not apply to a fixture located in an existing building where the chief building official is…

    Assessment

    Volume 1 prints “Table 7.6.41.6.-B” on PDF page 658. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Table 7.6.1.6.-B is printed on PDF page 659 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-056: Table 7.6.41.6.-B
    Source evidence · Volume 1, PDF page 658
  11. OBC-ERR-057Volume 1 · PDF page 668

    Printed text

    Table 2.6.3.4.

    Surrounding context

    …Notes to Table 7.6.3.4.: (1) Table 2.6.3.4. is not intended to limit water velocities that are permitted by Sentence 7.6.3.5.(1). 7.6.3.5. Velocity…

    Assessment

    Volume 1 prints “Table 2.6.3.4.” on PDF page 668. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Table 7.6.3.4. is printed on PDF page 668 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-057: Table 2.6.3.4.
    Source evidence · Volume 1, PDF page 668
  12. OBC-ERR-058Volume 1 · PDF page 669

    Printed text

    Sentence 7.1.5.3.(3)

    Surrounding context

    …7.7.1.4. Location of Outlets (1) Except as permitted in Sentence 7.1.5.3.(3), an outlet from a non-potable water system shall not be located where it can discharge into,…

    Assessment

    Volume 1 prints “Sentence 7.1.5.3.(3)” on PDF page 669 in Article 7.7.1.4. A full-volume search found no Article 7.1.5.3. or Sentence (3); the only occurrence is this citation. Its placement among adjacent 7.7.1 provisions strongly indicates a transposed identifier, but the exact intended Sentence cannot be reconstructed confidently, so no target is assigned.

    View the article on this site
    Evidence crop for OBC-ERR-058: Sentence 7.1.5.3.(3)
    Source evidence · Volume 1, PDF page 669
  13. OBC-ERR-062Volume 1 · PDF page 780

    Printed text

    Table 9.10.14.4.-A

    Surrounding context

    …with fire-resistance ratings not less than 45 min. (2) For the purpose of using Table 9.10.14.4.-A to determine the maximum aggregate area of unprotected openings permitted in an irregularly-shaped or skewed exterior wall, the location of the exposing building face shall be taken as a…

    Assessment

    Volume 1 prints “Table 9.10.14.4.-A” on PDF page 780. The exact kind-and-identifier combination has no matching target anywhere in the relevant PDF, while Table 9.10.14.4. is printed on PDF page 781 and matches the surrounding article, table, or provision. The component change is a localized transposition or typographical error in the printed reference, not a safe resolver alias.

    View the article on this site
    Evidence crop for OBC-ERR-062: Table 9.10.14.4.-A
    Source evidence · Volume 1, PDF page 780

Wrong kind or division

6 entries

References that name the wrong structural kind or Code division.

  1. OBC-ERR-013Volume 1 · PDF page 166

    Printed text

    Sentence 1.3.3.6.(1) of Division A

    Surrounding context

    …(1) If a floor area or part of a floor area has been designed for an occupant load other than that prescribed in Sentence 1.3.3.6.(1) of Division A or this Part, a permanent sign indicating that occupant load shall be posted in a conspicuous location.…

    Assessment

    Volume 1 prints “Sentence 1.3.3.6.(1) of Division A” on PDF page 166. Full-volume exact-number and hierarchy checks show that the only exact-number target is Sentence 1.3.3.6.(1) in Division C on PDF page 1127, not Division A; that Division C provision concerns an occupancy permit and is not a plausible silent substitute. The printed structural kind or Division is therefore wrong, and weakening kind/Division matching would create a legally misleading link.

    View the article on this site
    Evidence crop for OBC-ERR-013: Sentence 1.3.3.6.(1) of Division A
    Source evidence · Volume 1, PDF page 166
  2. OBC-ERR-033Volume 1 · PDF page 397

    Printed text

    Article 3.8.3.8.(7)

    Surrounding context

    …(b) have installed on each side, a vertically mounted grab bar that (i) complies with Article 3.8.3.8.(7), (ii) is not less than 600 mm long, with its centre line 1 000 mm above the finished floor, and…

    Assessment

    Volume 1 prints “Article 3.8.3.8.(7)” on PDF page 397. Full-volume exact-number and hierarchy checks show that the exact target is Sentence 3.8.3.8.(7), not an Article. The printed structural kind or Division is therefore wrong, and weakening kind/Division matching would create a legally misleading link.

    View the article on this site
    Evidence crop for OBC-ERR-033: Article 3.8.3.8.(7)
    Source evidence · Volume 1, PDF page 397
  3. OBC-ERR-063Volume 1 · PDF page 791

    Printed text

    Subsection 3.2.4., 3.2.7.8. and 3.2.7.10.

    Surrounding context

    …detection devices and systems are installed, these devices and systems and their installation shall conform to Subsection 3.2.4., 3.2.7.8. and 3.2.7.10. (See Note A-9.10.18.3.(1) (2) The following Articles in Subsection 3.2.4. regarding fire alarm systems do not apply to Part 9 buildings: Articles…

    Assessment

    Volume 1 prints “Subsection 3.2.4., 3.2.7.8. and 3.2.7.10.” on PDF page 791. Full-volume exact-number and hierarchy checks show that the exact target is Article 3.2.7.8., not a Subsection. The printed structural kind or Division is therefore wrong, and weakening kind/Division matching would create a legally misleading link.

    View the article on this site
    Evidence crop for OBC-ERR-063: Subsection 3.2.4., 3.2.7.8. and 3.2.7.10.
    Source evidence · Volume 1, PDF page 791
  4. OBC-ERR-064Volume 1 · PDF page 791

    Printed text

    Subsection 3.2.4., 3.2.7.8. and 3.2.7.10.

    Surrounding context

    …detection devices and systems are installed, these devices and systems and their installation shall conform to Subsection 3.2.4., 3.2.7.8. and 3.2.7.10. (See Note A-9.10.18.3.(1) (2) The following Articles in Subsection 3.2.4. regarding fire alarm systems do not apply to Part 9 buildings: Articles…

    Assessment

    Volume 1 prints “Subsection 3.2.4., 3.2.7.8. and 3.2.7.10.” on PDF page 791. Full-volume exact-number and hierarchy checks show that the exact target is Article 3.2.7.10., not a Subsection. The printed structural kind or Division is therefore wrong, and weakening kind/Division matching would create a legally misleading link.

    View the article on this site
    Evidence crop for OBC-ERR-064: Subsection 3.2.4., 3.2.7.8. and 3.2.7.10.
    Source evidence · Volume 1, PDF page 791
  5. OBC-ERR-071Volume 1 · PDF page 894

    Printed text

    Section 9.25.4.

    Surrounding context

    …(7.1) In unfinished basements, the protection required in Sentence (7) need not be provided for mineral fibre insulation, provided it is covered with a membrane which complies with the requirements of Section 9.25.4. (8) Insulation in factory-built buildings shall be installed so that it will not become dislodged during transportation.…

    Assessment

    Volume 1 prints “Section 9.25.4.” on PDF page 894. Full-volume exact-number and hierarchy checks show that the exact target is Subsection 9.25.4., not a Section. The printed structural kind or Division is therefore wrong, and weakening kind/Division matching would create a legally misleading link.

    View the article on this site
    Evidence crop for OBC-ERR-071: Section 9.25.4.
    Source evidence · Volume 1, PDF page 894
  6. OBC-ERR-077Volume 1 · PDF page 731

    Printed text

    Subsection 5.3.

    Surrounding context

    …the intended use of the interior space will result in high moisture generation shall be designed in conformance with Subsection 5.3. (See Note A-9.25.5.2.) Table 9.7.3.3.…

    Assessment

    Volume 1 prints “Subsection 5.3.” on PDF page 731. Full-volume exact-number and hierarchy checks show that the exact target is Section 5.3., not a Subsection. The printed structural kind or Division is therefore wrong, and weakening kind/Division matching would create a legally misleading link.

    View the article on this site
    Evidence crop for OBC-ERR-077: Subsection 5.3.
    Source evidence · Volume 1, PDF page 731