Division B

Part 9 - Housing and Small Buildings

Section 9.1. General
Add bookmark

9.1.1. Application
Add bookmark

9.1.1.1. Application
Add bookmark

(1)The application of this Part shall be as described in Subsection 1.3.3. of Division A.

9.1.1.2. Signs
Add bookmark

(1)Signs shall conform to the requirements in Section 3.15.

9.1.1.3. Self-Service Storage Buildings
Add bookmark

(1)Self-service storage buildings shall conform to the requirements in Section 3.10.

9.1.1.4. Tents and Air-Supported Structures
Add bookmark

(1)Tents shall conform to the requirements in Subsection 3.14.1.

(2)Air-supported structures shall conform to the requirements in Subsection 3.14.2.

9.1.1.5. Proximity to Existing Above Ground Electrical Conductors
Add bookmark

(1)Where a building is constructed in close proximity to existing above ground electrical conductors, the requirements of Subsection 3.1.20. shall apply.

9.1.1.6. Food Premises
Add bookmark

(1)The requirements of Subsection 3.7.6. apply to all food premises.

9.1.1.7. Radon
Add bookmark

(1)In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 200 Bq/m3 of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working levels inside the building for,

(a)the City of Elliot Lake in the Territorial District of Algoma,

(b)the Township of Faraday in the County of Hastings, and

(c)the geographic Township of Hyman in the Territorial District of Sudbury.

9.1.1.8. Building in Flood Plains
Add bookmark

(1)Buildings constructed on flood plains shall,

(a)be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and

(b)incorporate floodproofing measures that will preserve the integrity of exits and means of egress during times of flooding.

9.1.1.9. Site Assembled and Factory-Built Buildings (See Note A-9.1.1.9.)
Add bookmark

(1)Except as provided in Sentence (2) and in Sentences 12.2.1.2.(1) and (2), a manufactured building is deemed to comply with this Code if it is designed and constructed in compliance with,

(a)CSA Z240.2.1, “Structural requirements for manufactured homes,” if the building is constructed in sections not wider than 4.88 m, or

(b)CSA A277, “Procedure for certification of prefabricated buildings, modules, and panels.”

(2)The requirements of this Code shall apply to,

(a)building components designed and constructed outside the place of manufacture, and

(b)site installation of such buildings.

9.1.1.10. Public Pools and Public Spas
Add bookmark

(1)Public pools shall conform to the requirements of Section 3.11. and public spas shall conform to the requirements of Section 3.12.

9.1.1.11. Shelf and Rack Storage Systems
Add bookmark

(1)Shelf and rack storage systems shall conform to the requirements of Section 3.16.

Section 9.2. Definitions
Add bookmark

9.2.1. General
Add bookmark

9.2.1.1. Defined Words
Add bookmark

(1)Words in italics are defined in Article 1.4.1.2. of Division A.

Section 9.3. Materials, Systems and Equipment
Add bookmark

9.3.1. Concrete
Add bookmark

9.3.1.1. General
Add bookmark

(1)Except as provided in Sentence (2) and Articles 9.3.1.6. and 9.3.1.7., unreinforced and nominally reinforced concrete shall be designed, mixed, placed, cured and tested in accordance with the requirements for “R” class concrete stated in Section 9 of CSA A23.1, “Concrete materials and methods of concrete construction.”

(2)Unreinforced and nominally reinforced site-batched concrete shall be designed, mixed, placed and cured in accordance with Articles 9.3.1.2. to 9.3.1.9.

(3)Except as provided in Sentence (4), Subsection 9.15.4. and Section 9.40., reinforced concrete shall be designed to conform to the requirements of Part 4.

(4) For flat insulating concrete form walls not exceeding 2 storeys in building height and having a maximum floor to floor height of 3 m, in buildings of light-frame construction, the concrete and reinforcing shall comply with Part 4 or

(a)the concrete shall conform to CSA A23.1, “Concrete materials and methods of concrete construction,” with a maximum aggregate size of 19 mm, and

(b)the reinforcing shall,

(i)conform to CSA G30.18, “Carbon steel bars for concrete reinforcement”,

(ii)have a minimum specified yield strength of 400 MPa, and

(iii)be lapped a minimum of 450 mm for 10M bars and 650 mm for 15M bars. (See also Articles 9.15.4.5. and 9.20.17.2. to 9.20.17.4.)

9.3.1.2. Cement
Add bookmark

(1)Cement shall meet the requirements of CSA A3001, “Cementitious materials for use in concrete.”

9.3.1.3. Concrete in Contact With Sulfate Soil
Add bookmark

(1)Concrete in contact with sulphate soil, which is deleterious to normal cement, shall conform to the requirements in Clause 4.1.1.6 of CSA A23.1, “Concrete materials and methods of concrete construction.”

9.3.1.4. Aggregates
Add bookmark

(1)Aggregates shall

(a)consist of sand, gravel, crushed rock, crushed air-cooled blast furnace slag, expanded shale or expanded clay conforming to CSA A23.1, “Concrete materials and methods of concrete construction,” and

(b)be clean, well-graded and free of injurious amounts of organic and other deleterious material.

9.3.1.5. Water
Add bookmark

(1)Water shall be clean and free of injurious amounts of oil, organic matter, sediment or any other deleterious material.

9.3.1.6. Compressive Strength
Add bookmark

(See also Article 9.12.4.1., Sentence 9.15.4.2.(1) and Article 9.18.6.1.)

(1)Except as provided elsewhere in this Part, the compressive strength of unreinforced concrete after 28 days shall be not less than,

(a)32 MPa for garage floors, carport floors and all exterior flatwork,

(b)20 MPa for interior floors other than those for garages and carports, and

(c)15 MPa for all other applications.

(2)Site-batched concrete used for garage floors, carport floors and exterior flatwork shall have air entrainment of 5 to 8%.

9.3.1.7. Concrete Mixes (See Note A-9.3.1.7.)
Add bookmark

(1)For pre-mixed concrete and for the site-batched concrete mixes described in Table 9.3.1.7., the maximum ratio of water to cementing materials measured by weight shall not exceed

(a)0.45 for garage floors, carport floors and all exterior flatwork,

(b)0.65 for interior floors other than those for garages and carports, and

(c)0.70 for all other applications.

(2)The size of aggregate in unreinforced site-batched concrete mixes referred to in Sentence (1) shall not exceed,

(a)1/5 the distance between the sides of vertical forms, or

(b)1/3 the thickness of flatwork.

Table 9.3.1.7. Site-Batched Concrete MixesForming Part of Sentence 9.3.1.7.(1)
Maximum Size of Coarse Aggregate, mmMaterials, volume
Cementing MaterialFine Aggregate (damp average coarse sand)Coarse Aggregate (gravel or crushed stone)
Parts(1)LPartsLPartsL
141281.7549256
201281.75492.570
28128256384
401282563.598

Notes to Table 9.3.1.7.:

(1)
1 part cementing material = 1 × 40 kg bag

9.3.1.8. Admixtures
Add bookmark

(1)Admixtures shall conform to ASTM C260 / C260M, “Standard Specification for Air-Entraining Admixtures for Concrete,” or ASTM C494 / C494M, “Standard Specification for Chemical Admixtures for Concrete,” as applicable.

9.3.1.9. Cold Weather Requirements
Add bookmark

(1)When the air temperature is below 5°C, concrete shall be

(a)kept at a temperature of not less than 10°C or more than 25°C while being mixed and placed, and

(b)maintained at a temperature of not less than 10°C for 72 h after placing.

(2)No frozen material or ice shall be used in concrete described in Sentence (1).

9.3.2. Lumber and Wood Products
Add bookmark

9.3.2.1. Grade Marking
Add bookmark

(1)Lumber for joists, rafters, trusses and beams and for the uses listed in Table 9.3.2.1. shall be identified by a grade stamp to indicate its grade as determined by the NLGA, “Standard Grading Rules for Canadian Lumber.” (See Note A-9.3.2.1.(1))

Table 9.3.2.1. Minimum Lumber Grades for Specific End UsesForming Part of Sentences 9.3.2.1.(1) and 9.3.2.2.(1)
UseBoards(1)Framing
Paragraph in the NLGA Grading Rules Under Which Boards are GradedAll Species
All SpeciesEastern White Pine & Red Pine
Para 113Para 114Para 118
Stud wall framing (loadbearing members)———Stud, Standard, No. 2
Stud wall framing (non-loadbearing members)———Stud, Utility, No. 3
Plank frame construction (loadbearing members)No. 3 Common—No. 3 CommonNo. 2
Plank frame construction (non-loadbearing members)No. 5 Common—No. 5 CommonEconomy, No. 3
Post and beams less than 114 mm in thickness———Standard, No.2
Post and beams not less than 114 mm in thickness———Standard
Roof sheathingNo. 3 CommonStandardNo. 4 Common—
SubflooringNo. 3 CommonStandardNo. 3 Common—
Wall sheathing when required as a nailing baseNo. 4 CommonUtilityNo. 4 Common—
Wall sheathing not required as a nailing baseNo. 5 CommonEconomyNo. 5 Common—

Notes to Table 9.3.2.1.:

(1)
See Note A-Table 9.3.2.1.

9.3.2.2. Lumber Grades
Add bookmark

(1)Except for joists, rafters, trusses and beams, visually graded lumber shall conform to the grades in Table 9.3.2.1. (See Article 9.23.4.2. for joists, rafters and beams and Article 9.23.14.11. for trusses.)

9.3.2.3. Machine Stress Rated Lumber
Add bookmark

(1)Machine stress rated lumber shall conform to the requirements of Subsection 4.3.1.

9.3.2.4. OSB, Waferboard and Plywood Marking
Add bookmark

(1)OSB, waferboard and plywood used for roof sheathing, wall sheathing and subflooring shall be legibly identified on the face of the material indicating,

(a)the manufacturer of the material,

(b)the standard to which it is produced, and

(c)that the material is of an exterior type.

9.3.2.5. Moisture Content
Add bookmark

(1)Moisture content of lumber shall be not more than 19% at the time of installation.

9.3.2.6. Lumber Dimensions
Add bookmark

(1)Lumber dimensions referred to in this Part are actual dimensions determined in conformance with CSA O141, “Softwood Lumber.”

9.3.2.7. Panel Thickness Tolerances
Add bookmark

(1)The thicknesses specified in this Part for plywood, hardboard, particleboard, OSB and waferboard shall be subject to the tolerances permitted in the standards referenced for these products unless specifically indicated herein.

9.3.2.8. Undersized Lumber
Add bookmark

(1)Joist, rafter, lintel and beam members up to 5% less than the actual Canadian standard sizes are permitted to be used provided the allowable spans for the grade and species of lumber under consideration are reduced 5% from those shown in the Span Tables for full size members. (See Note A-9.3.2.8.(1))

9.3.2.9. Termite and Decay Protection
Add bookmark

(1)In localities where termites are known to occur,

(a)clearance between structural wood elements and the finished ground level directly below them shall be not less than 450 mm and, except as provided in Sentence (2), all sides of the supporting elements shall be visible to permit inspection, or

(b)structural wood elements, supported by elements in contact with the ground or exposed over bare soil, shall be pressure-treated with a chemical that is toxic to termites.

(See Note A-9.3.2.9.(1))

(2)In localities where termites are known to occur and foundations are insulated or otherwise finished in a manner that could conceal a termite infestation,

(a)a metal or plastic barrier shall be installed through the insulation and any other separation or finish materials above finished ground level to control the passage of termites behind or through the insulation, separation or finish materials, and

(b)all sides of the finished supporting assembly shall be visible to permit inspection.

(3)Structural wood elements shall be pressure-treated with a preservative to resist decay where the vertical clearance between structural wood elements and the finished ground level is less than 150 mm. (See Note A-9.3.2.9.(3))

(3.1)In localities where termites are known to occur and where windows or other openings at or below grade contain wood elements, the bottom of window wells or adjacent ground shall be at least 150 mm below the nearest wood unless the wood is pressure-treated with a chemical toxic to termites.

(4)Structural wood elements used in retaining walls and cribbing shall be pressure-treated with a preservative to resist decay, where

(a)the retaining wall or cribbing supports ground that is critical to the stability of building foundations, or

(b)the retaining wall or cribbing is greater than 1.2 m in height.

(See Note A-9.3.2.9.(4))

(5)Where wood is required by this Article to be treated to resist termites or decay, such treatment shall be in accordance with Table 2, “Use Categories for Specific Products, Uses, and Exposures,” of CAN/CSA-O80.1, “Specification of treated wood,” as follows:

(a)Use Category 1 (UC1), where the wood member is used in

(i)interior construction,

(ii)above-ground applications, and

(iii)applications where the wood member remains dry,

(b)Use Category 2 (UC2), where the wood member is used in

(i)interior construction,

(ii)above-ground applications, and

(iii)applications where the wood member may be subjected to occasional sources of moisture,

(c)Use Category 3.2 (UC3.2), where the wood member is used in

(i)exterior construction,

(ii)above-ground applications, and

(iii)applications where the wood member is uncoated or is used in a configuration conducive to moisture accumulation,

(d)Use Category 4.1 (UC4.1), where

(i)the wood member is used in contact with the ground,

(ii)the wood member is used in contact with fresh water, or

(iii)the vertical clearance between the wood element and the finished ground level is less than 150 mm and the wood elements are not separated from permeable supporting materials by a moisture barrier, or

(e)Use Category 4.2 (UC4.2), where the wood member is used in critical structural components, including permanent wood foundations.

(6)Where wood is protected in accordance with UC1 or UC2 using an inorganic boron preservative, the wood shall be

(a)protected from direct exposure to water during and after the completion of construction, and

(b)separated from permeable supporting materials by a moisture barrier that is resistant to all expected mechanisms of deterioration in the service environment if the vertical clearance to the ground is less than 150 mm.

(7)Wood that is required by this Article to be treated to resist termites or decay shall be identified by a mark to indicate the type of preservative used and conformance to the relevant required Use Category.

9.3.3. Metal
Add bookmark

9.3.3.1. Sheet Metal Thickness
Add bookmark

(1)Minimum thicknesses for sheet metal material that are stated in this Part refer to the actual minimum base metal thicknesses measured at any point of the material, and in the case of galvanized steel described in Sentence 9.3.3.2.(1), include the thickness of the galvanizing coating unless otherwise indicated.

9.3.3.2. Galvanized Sheet Steel
Add bookmark

(1)Where sheet steel is required to be galvanized, it shall be metallic-coated with zinc or an alloy of 55% aluminum-zinc meeting the requirements of

(a)ASTM A653 / A653M, “Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process,” or

(b)ASTM A792 / A792M, “Standard Specification for Sheet Steel, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process.”

(2)Where galvanized sheet steel is intended for use in locations exposed to the weather or as a flashing material, it shall have a zinc coating not less than the G90 (Z275) coating designation or an aluminum-zinc alloy coating not less than the AZM150 coating designation, as referred to in Sentence (1).

Section 9.4. Structural Requirements
Add bookmark

9.4.1. Structural Design Requirements and Application Limitations
Add bookmark

9.4.1.1. General (See Note A-9.4.1.1.)
Add bookmark

(1)Subject to the application limitations defined elsewhere in this Part, structural members and their connections shall

(a)conform to requirements provided elsewhere in this Part,

(b)be designed according to good engineering practice such as provided in the CWC 2014, “Engineering Guide for Wood Frame Construction,” or

(c)be designed according to Part 4 using the loads and deflection and vibration limits specified in,

(i)this Part, or

(ii)Part 4.

(2)Where floor framing is designed in accordance with Clause (1)(b) or (c) and where supporting wall framing and fastenings, or footings, are designed according to Clause (1)(a), the maximum specified live load on the floor according to Table 4.1.5.3. shall not exceed 2.4 kPa.

(3)Location-specific information for structural design, including snow and wind loads and seismic spectral response accelerations, shall be determined according to MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”

(See Note A-9.4.1.1.(3))

9.4.2. Specified Loads
Add bookmark

9.4.2.1. Application (See Note A-9.4.2.1. and 9.4.2.2.)
Add bookmark

(1)This Subsection applies to light-frame construction whose wall, floor and roof planes are generally comprised of frames of small repetitive structural members, and where

(a)the roof and wall planes are clad, sheathed or braced on at least one side,

(b)the small repetitive structural members are spaced not more than 600 mm o.c.,

(c)the clear span of any structural member does not exceed 12.2 m,

(d)the maximum deflection of the structural roof members conforms to Article 9.4.3.1.,

(e)the maximum total roof area, notwithstanding any separation of adjoining buildings by firewalls, is 4 550 m2, and

(f)for flat roofs, there are no significant obstructions on the roof, such as parapet walls, spaced closer than the distance calculated by Do = 10(Ho – 0.8 Ss / γ) where Do = minimum distance between obstructions, m, Ho = height of the obstruction above the roof, m, Ss = ground snow load, kPa, and γ = specific weight of snow taken as 4.0 kN/m3 or 0.43Ss + 2.2 kN/m3, whichever is lesser.

9.4.2.2. Specified Snow Loads (See Note A-9.4.2.1. and 9.4.2.2.)
Add bookmark

(1)Except as provided in Sentences (2) and (4), specified snow loads shall be not less than those calculated using the following formula:

S = CbSs + Sr

where

S = specified snow load,

Cb = basic snow load roof factor, which is 0.45 where the entire width of a roof does not exceed 4.3 m and 0.55 for all other roofs,

Ss = 1-in-50 year ground snow load in kPa, determined according to MMAH Supplementary Standard SB-1, “Climatic and Seismic Data,” and

Sr = associated 1-in-50 year rain load in kPa, determined according to MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”

(2)In no case shall the specified snow load be less than 1 kPa.

(3)Bow string, arch or semi-circular roof trusses having an unsupported span greater than 6 m shall be designed in conformance with the snow load requirements in Subsection 4.1.6.

(4)Where the height of a roof step at the intersection of an upper level roof and a lower level roof is greater than 2 m, and the upper level roof has a slope less than 1 in 6 and an area greater than 600 m2, the specified snow load on the lower level roof shall be

(a)for distances from the roof step that are less than or equal to the drift length, xd, calculated in accordance with Sentence (5), not less than 1.5 times the specified snow load, S, calculated using the formula in Sentence (1) with Cb equal to 0.55, and

(b)for distances from the roof step that are greater than the drift length, xd, calculated in accordance with Sentence (5), as specified in Sentence (1).

(5)For the purposes of Sentence (4), the drift length, xd, in m, shall be calculated as follows: xd = 5(h − 0.55Ss / γ) where h = height of the roof step, in m, and γ = specific weight of snow as specified in Clause 9.4.2.1.(1)(f).

9.4.2.3. Platforms Subject to Snow and Occupancy Loads
Add bookmark

(1)Balconies, decks and other accessible exterior platforms intended for an occupancy and subject to snow loads shall be designed to carry the specified roof snow load or 1.9 kPa, whichever is greater, where the platform, or each segregated area of the platform, serves a single dwelling unit. (See Note A-9.4.2.3.(1))

9.4.2.4. Attics and Roof Spaces
Add bookmark

(1)Ceiling joists or truss bottom chords in residential attic or roof spaces having limited accessibility that precludes the storage of equipment or material shall be designed for a total specified load of not less than 0.35 kPa, where the total specified load is the sum of the specified dead load plus the specified live load of the ceiling. (See Note A-9.4.2.4.(1))

9.4.3. Deflections
Add bookmark

9.4.3.1. Deflections
Add bookmark

(1)The maximum deflection of structural members shall conform to Table 9.4.3.1.

(2)Dead loads need not be considered in computing deflections referred to in Sentence (1).

Table 9.4.3.1. Maximum DeflectionsForming Part of Sentence 9.4.3.1.(1)
Structural MembersType of Ceiling SupportedMax. Allowable Deflection as an Expressed Ratio of the Clear Span
Roof rafters, roof joists and roof beamsNo ceiling1/180
Other than plaster or gypsum board1/240
Plaster or gypsum board1/360
Ceiling joistsOther than plaster or gypsum board1/240
Plaster or gypsum board1/360
Floor beams, floor joists and floor deckingAll cases1/360
Beams, joists and decking for balconies, decks and other accessible exterior platformsServing a single dwelling unit1/240
Other1/360

9.4.4. Foundation Conditions
Add bookmark

9.4.4.1. Allowable Bearing Pressures
Add bookmark

(1)Footing sizes for shallow foundations shall be

(a)determined in accordance with Section 9.15., or

(b)designed in accordance with Section 4.2. using,

(i)the maximum allowable bearing pressures in Table 9.4.4.1., or

(ii)allowable bearing pressures determined from subsurface investigation.

(2)The design procedures described in Section 4.2. are permitted to be used in lieu of the design procedures in this Subsection.

Table 9.4.4.1. Allowable Bearing Pressure for Soil or RockForming Part of Sentence 9.4.4.1.(1)
Type and Condition of Soil or RockMaximum Allowable Bearing Pressure, kPa
Dense or compact sand or gravel(1)150
Loose sand or gravel(1)50
Dense or compact silt(1)100
Stiff clay(1)150
Firm clay(1)75
Soft clay(1)40
Till200
Clay shale300
Sound rock500

Notes to Table 9.4.4.1.:

(1)
See Note A-Table 9.4.1.1.

(3)The design procedures described in Section 4.2. shall be used where,

(a)deep foundations are used,

(b)the footing size falls outside the scope of this Section, or

(c)the foundation is constructed on peat, filled ground or on sensitive clays as described in Article 9.15.1.1.

9.4.4.2. Foundation Capacity in Weaker Soil and Rock
Add bookmark

(1)Where a soil or rock within a distance equal to twice the footing width below the bearing surface has a lower allowable bearing pressure than that at the bearing surface as shown in Article 9.4.4.1., the design capacity of the foundation shall not be greater than would cause the weakest soil or rock to be stressed beyond its allowable bearing pressure.

(2)In calculating subsurface pressures referred to in Sentence (1), the loads from the footings shall be assumed to be distributed uniformly over a horizontal plane within a frustum extending downward from the footing at an angle of 60° to the horizontal.

9.4.4.3. High Water Table
Add bookmark

(1)Where a foundation bears on gravel, sand or silt, and the water table is within a distance below the bearing surface equal to the width of the foundation, the allowable bearing pressure shall be 50% of that determined in Article 9.4.4.1.

9.4.4.4. Soil Movement
Add bookmark

(1)Where a foundation is located in an area where soil movement caused by changes in soil moisture content, freezing, or chemical-microbiological oxidation is known to occur to the extent that it will damage a building, measures shall be taken to preclude such movement or to reduce the effects on the building so that the building’s stability and the performance of assemblies will not be adversely affected. (See Note A-9.4.4.4.(1))

9.4.4.5. Reserved
Add bookmark

9.4.4.6. Walls Supporting Drained Earth (See Note A-9.4.4.6. and 9.15.1.1.)
Add bookmark

(1)Except where constructed in accordance with Section 9.15., walls supporting drained earth shall be designed

(a)for a pressure equivalent to that exerted by a fluid with a density of not less than 480 kg/m3 and a depth equal to that of the retained earth, or

(b)in accordance with Section 4.2. so as to be able to resist the loads and effects described in Article 4.1.2.1.

(2)Walls supporting other than drained earth shall be designed

(a)for the pressure described in Clause (1)(a) plus the fluid pressure of the surcharge, or

(b)in accordance with Section 4.2. so as to be able to resist the loads and effects described in Article 4.1.2.1.

Section 9.5. Design of Areas, Spaces and Doorways
Add bookmark

9.5.1. General
Add bookmark

9.5.1.0A. Application
Add bookmark

(1)Except as otherwise specified in this Part, this Section applies only to dwelling units that are intended for use on a continuing or year-round basis as the principal residence of the occupant.

9.5.1.1. Method of Measurement
Add bookmark

(1)Except as otherwise specified in this Part, the areas, dimensions and heights of rooms or spaces shall be measured between finished wall surfaces and between finished floor and ceiling surfaces.

9.5.1.1A. Floor Areas
Add bookmark

(1)Minimum floor areas specified in this Section do not include closets or built-in bedroom cabinets unless otherwise indicated.

9.5.1.2. Combination Rooms (See Note A-9.5.1.2.)
Add bookmark

(1)Two or more areas may be considered as a combination room if the opening between the areas occupies the larger of 3 m2 or 40% or more of the wall measured on the side of the dependent area.

(2)Where the dependent area is a bedroom, direct passage shall be provided between the two areas.

(3)The opening required in Sentence (1) shall not contain doors or windows.

9.5.1.3. Lesser Areas and Dimensions
Add bookmark

(1)Areas of rooms and spaces are permitted to be less than required in this Section provided it can be shown that the rooms and spaces are adequate for their intended use, such as by the provision of built-in furniture to compensate for reduced sizes.

9.5.2. Barrier-Free Design
Add bookmark

9.5.2.1. General
Add bookmark

(1)Except as provided in Sentence (2) and Article 3.8.1.1., every building shall be designed in conformance with Section 3.8.

(2)The requirements of Section 3.8. need not be provided for detached houses, semi-detached houses, houses with a secondary suite, duplexes, triplexes, row houses and boarding or rooming houses with fewer than eight boarders or roomers.

9.5.2.2. Protection on Floor Areas With a Barrier-Free Path of Travel
Add bookmark

(1)Where a barrier-free path of travel required in Article 9.5.2.1. is provided to any storey above the first storey, the requirements in Article 3.3.1.7. shall apply.

9.5.2.3. Reserved
Add bookmark

9.5.2.4. Stud Wall Reinforcement
Add bookmark

(1)If wood wall studs or sheet steel wall studs enclose the main bathroom in a dwelling unit, reinforcement shall be installed to permit the future installation of the following:

(a)for a water closet, a grab bar described in Clauses 3.8.3.8.(3)(a) and a grab bar described in Clause 3.8.3.8.(3)(c),

(b)for a shower, a grab bar described in Clause 3.8.3.13.(2)(g), and

(c)for a bathtub, a grab bar described in Clause 3.8.3.13.(7)(e).

(See Note A-9.5.2.4.(1))

9.5.3. Ceiling Heights
Add bookmark

9.5.3.1. Ceiling Heights of Rooms or Spaces
Add bookmark

(1)Except as provided in Sentences (2) and (3), the ceiling heights and clear heights in rooms or spaces in residential occupancies and live/work units shall conform to Table 9.5.3.1.

(2)Ceiling heights in secondary suites shall be not less than 1.95 m.

(3)Clear heights under beams and ducting in secondary suites shall be not less than 1.85 m.

(4)Areas in rooms or spaces over which ceiling height and clear height are not less than the minimum specified in Table 9.5.3.1. or Sentence (2) or (3) shall be contiguous with the entry or entries to those rooms or spaces.

Table 9.5.3.1. Room Ceiling HeightsForming Part of Sentences 9.5.3.1.(1) and (4)
Room or SpaceMinimum Heights(1)
Living room or space, dining room or space, kitchen or kitchen space2 300 mm over at least 75% of the required floor area with a clear height of 2 100 mm at any point over the required area
Bedroom or bedroom space2 300 mm over at least 50% of the required area or 2 100 mm over all of the required floor area. Any part of the floor having a clear height of less than 1 400 mm shall not be considered in computing the required floor area
Basement space2 100 mm over at least 75% of the basement area except that under beams and ducts the clearance is permitted to be reduced to 1 950 mm
Bathroom, water closet room or laundry area above grade2 100 mm in any area where a person would normally be in a standing position
Passage, hall or main entrance vestibule and finished rooms not specifically mentioned above2 100 mm

Notes to Table 9.5.3.1.:

(1)
Area of the space shall be measured at floor level.

9.5.3.2. Mezzanines
Add bookmark

(1)The ceiling height above and below a mezzanine floor assembly in all occupancies shall be not less than 2.1 m.

9.5.3.3. Storage Garages
Add bookmark

(1)The clear height in a storage garage shall be not less than 2 m.

9.5.3A. Living Rooms or Spaces Within Dwelling Units
Add bookmark

9.5.3A.1. Areas of Living Rooms and Spaces
Add bookmark

(1)Living areas within dwelling units, either as separate rooms or in combination with other spaces, shall have an area not less than 13.5 m².

(2)Where the area of a living space is combined with a kitchen and dining area, the living area alone in a dwelling unit that contains sleeping accommodation for not more than two persons shall be not less than 11 m².

9.5.3B. Dining Rooms or Spaces Within Dwelling Units
Add bookmark

9.5.3B.1. Area of Dining Rooms or Spaces
Add bookmark

(1)A dining space in combination with other space shall have an area of not less than 3.25 m².

(2)Dining rooms not combined with other space shall have a minimum area of 7 m².

9.5.3C. Kitchens Within Dwelling Units
Add bookmark

9.5.3C.1. Kitchen Areas
Add bookmark

(1)Kitchen areas within dwelling units either separate from or in combination with other spaces, shall have an area of not less than 4.2 m² including the area occupied by the base cabinets, except that in dwelling units containing sleeping accommodation for not more than two persons, the minimum area shall be 3.7 m².

9.5.3D. Bedrooms or Spaces in Dwelling Units and Dormitories
Add bookmark

9.5.3D.1. Areas of Bedrooms
Add bookmark

(1)Except as provided in Articles 9.5.3D.2. and 9.5.3D.3., bedrooms in dwelling units shall have an area not less than 7 m² where built-in cabinets are not provided and not less than 6 m² where built-in cabinets are provided.

9.5.3D.2. Areas of Master Bedrooms
Add bookmark

(1)Except as provided in Article 9.5.3D.3., at least one bedroom in every dwelling unit shall have an area of not less than 9.8 m² where built-in cabinets are not provided and not less than 8.8 m² where built-in cabinets are provided.

9.5.3D.3. Areas of Combination Bedrooms
Add bookmark

(1)Bedroom spaces in combination with other spaces in dwelling units shall have an area not less than 4.2 m².

9.5.3D.4. Areas of Other Sleeping Rooms
Add bookmark

(1)Sleeping rooms other than in dwelling units shall have an area not less than 7 m² per person for single occupancy and 4.6 m² per person for multiple occupancy.

9.5.3D.5. Recreational Camps
Add bookmark

(1)Recreational camps shall have an area in the sleeping quarters of at least 3.72 m² per camper or, if double or triple tier bunk units are used, 2.79 m² per camper.

9.5.3D.6. Camps for Housing Workers
Add bookmark

(1)A camp for housing of workers shall have a minimum area of 3.72 m² per employee in every room used for sleeping purposes.

9.5.3E. Combined Spaces
Add bookmark

9.5.3E.1. Combined Living, Dining, Bedroom and Kitchen Spaces
Add bookmark

(1)Despite Subsections 9.5.3A. to 9.5.3D., where living, dining, bedroom and kitchen spaces are combined in a dwelling unit that contains sleeping accommodation for not more than two persons, the area of the combined spaces shall be not less than 13.5 m2.

9.5.3F. Bathrooms and Water Closet Rooms
Add bookmark

9.5.3F.1. Space to Accommodate Fixtures
Add bookmark

(1)In every dwelling unit an enclosed space of sufficient size shall be provided to accommodate a water closet, lavatory and bathtub or shower stall.

9.5.3F.2. Doors to Rooms Containing Water Closets
Add bookmark

(1)A door shall be provided to each room containing a water closet within a dwelling unit.

9.5.4. Hallways
Add bookmark

9.5.4.1. Hallway Width
Add bookmark

(1)The unobstructed width of a hallway within a dwelling unit shall be not less than 860 mm, except that the hallway width is permitted to be 710 mm where

(a)there are only bedrooms and bathrooms at the end of the hallway furthest from the living area, and

(b)a second exit is provided

(i)in the hallway near the end furthest from the living area, or

(ii)in each bedroom served by the hallway.

9.5.5. Doorway Sizes
Add bookmark

9.5.5.1. Doorway Opening Sizes
Add bookmark

(1)Except as provided in Sentence (2) and Articles 9.5.5.3., 9.9.6.2. and 9.9.6.3., doorway openings within dwelling units and within houses with a secondary suite including their common spaces shall be designed to accommodate at least the door sizes given in Table 9.5.5.1. for swing-type and folding doors.

(2)Doorway openings within secondary suites shall be designed to accommodate swing-type and folding doors not less than 1 890 mm high where the ceiling height complies with Sentence 9.5.3.1.(2).

Table 9.5.5.1. Minimum Door SizesForming Part of Sentence 9.5.5.1.(1)
At Entrance to:Minimum Width, mmMinimum Height, mm
Dwelling unit or house with a secondary suite including common spaces (required entrance)
Vestibule or entrance hall
8101 980
Stairs to a floor level that contains a finished space
All doors in at least one line of passage from the exterior to the basement
Utility rooms
8101 980
Walk-in closet6101 980
Bathroom, water-closet room, shower room(1)6101 980
Rooms located off hallways that are permitted to be 710 mm wide6101 980
Rooms not mentioned above, exterior balconies7601 980

Notes to Table 9.5.5.1.:

9.5.5.2. Doors to Public Water-Closet Rooms
Add bookmark

(1)Doors to public water closet rooms shall be not less than 810 mm wide and 2 030 mm high.

9.5.5.3. Doors to Bathrooms
Add bookmark

(1)Where a barrier-free path of travel conforming to Section 3.8. is provided into a suite of residential occupancy and where a bathroom within the suite is at the level of the suite entrance door, the doorway to such bathroom and to each bedroom at the same level as such bathroom shall have, when the door is in the open position, a clear width of not less than,

(a)760 mm where the door is served by a corridor or space not less than 1 060 mm wide, and

(b)810 mm where the door is served by a corridor or space less than 1 060 mm wide.

Section 9.6. Glass
Add bookmark

9.6.1. General
Add bookmark

9.6.1.1. Application
Add bookmark

(1)This Section applies to

(a)glass in

(i)interior doors and interior windows and their sidelights,

(ii)clothes closets,

(iii)site-built exterior windows, doors and skylights,

(iv)shower or bathtub enclosures,

(v)glazed panels and partitions, and

(b)the protection of glass.

9.6.1.2. Material Standards for Glass
Add bookmark

(1)Glass shall conform to

(a)CAN/CGSB-12.1, “Safety Glazing,”

(b)CAN/CGSB-12.2-M, “Flat, Clear Sheet Glass,”

(c)CAN/CGSB-12.3-M, “Flat, Clear Float Glass,”

(d)CAN/CGSB-12.4-M, “Heat Absorbing Glass,”

(e)CAN/CGSB-12.8, “Insulating glass units,”

(f)CAN/CGSB-12.9, “Spandrel glass,”

(g)CAN/CGSB-12.10-M, “Glass, Light and Heat Reflecting,”

(h)CAN/CGSB-12.11-M, “Wired Safety Glass,” or

(i)ASTM E2190, “Standard Specification for Insulating Glass Unit Performance and Evaluation.”

(2)Mirrored glass doors are only permitted to be used only at the entrance to clothes closets and shall conform to the requirements of CAN/CGSB-82.6-M, “Doors, Mirrored Glass, Sliding or Folding, Wardrobe.” (See Note A-9.6.1.2.(2))

(3)Mirrored glass doors reinforced with a film backing shall meet the impact resistance requirements specified in CAN/CGSB-12.5-M, “Mirrors, Silvered.”

9.6.1.3. Structural Sufficiency of Glass
Add bookmark

(1)Except as provided in Sentence (2), glass shall be designed in conformance with Article 4.3.6.1.

(2)Where the building has an essentially uniform distribution of paths for air leakage, including operable openings, but no large openings that would permit wind gusts to rapidly enter the building and the building is not in an exceptionally exposed location such as a hilltop, the maximum area of individual panes of glass for windows shall conform to

(a)Tables 9.6.1.3.-A to 9.6.1.3.-C, where the building has a height from grade to the uppermost roof of 12 m or less, and is located in a built-up area, no less than 120 m away from the boundary between this area and open terrain, or

(b)Tables 9.6.1.3.-D to 9.6.1.3.-F.

(See Note A-9.6.1.3.(2))

(3)The maximum area of individual panes of glass for doors shall conform to Table 9.6.1.3.-G.

Table 9.6.1.3.-A Maximum Glass Area for Windows in Areas for which the 1-in-50 Hourly Wind Pressure (HWP) is Less than 0.55 kPa(1)Forming Part of Clause 9.6.1.3.(2)(a)
Type of GlassMaximum Glass Area, m2
Glass Thickness, mm
2.5345681012
Annealed0.580.961.472.042.844.746.659.74
Factory-sealed insulated glass (IG) units(2)1.021.712.683.745.247.939.9213.92
Heat-strengthened or tempered1.241.932.603.183.995.556.999.74
Wired0.270.450.680.931.312.153.075.03

Notes to Table 9.6.1.3.-A:

(1)
The maximum hourly wind pressure with one chance in fifty of being exceeded in any one year, as provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”
(2)
Maximum glass area values apply to IG units of two identical lites (annealed, heat-strengthened or tempered) spaced at 12.7 mm.
Table 9.6.1.3.-B Maximum Glass Area for Windows in Areas for which the 1-in-50 Hourly Wind Pressure (HWP) is Less than 0.75 kPa(1)Forming Part of Clause 9.6.1.3.(2)(a)
Type of GlassMaximum Glass Area, m2
Glass Thickness, mm
2.5345681012
Annealed0.420.681.021.422.043.344.707.65
Factory-sealed insulated glass (IG) units(2)0.721.191.852.563.646.018.3511.83
Heat-strengthened0.881.462.212.713.394.735.928.29
Tempered1.181.642.212.713.394.735.928.29
Wired0.200.320.500.680.941.552.193.60

Notes to Table 9.6.1.3.-B:

(1)
The maximum hourly wind pressure with one chance in fifty of being exceeded in any one year, as provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”
(2)
Maximum glass area values apply to IG units of two identical lites (annealed, heat-strengthened or tempered) spaced at 12.7 mm.
Table 9.6.1.3.-C Maximum Glass Area for Windows in Areas for which the 1-in-50 Hourly Wind Pressure (HWP) is Less than 1.00 kPa(1)Forming Part of Clause 9.6.1.3.(2)(a)
Type of GlassMaximum Glass Area, m2
Glass Thickness, mm
2.5345681012
Annealed0.300.500.771.051.452.403.405.62
Factory-sealed insulated glass (IG) units(2)0.520.861.311.862.574.306.109.89
Heat-strengthened0.651.041.632.262.924.075.107.14
Tempered1.011.421.902.332.924.075.107.14
Wired0.160.260.380.520.711.151.632.69

Notes to Table 9.6.1.3.-C:

(1)
The maximum hourly wind pressure with one chance in fifty of being exceeded in any one year, as provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”
(2)
Maximum glass area values apply to IG units of two identical lites (annealed, heat-strengthened or tempered) spaced at 12.7 mm.
Table 9.6.1.3.-D Maximum Glass Area for Windows in Areas for which the 1-in-50 Hourly Wind Pressure (HWP) is Less than 0.55 kPa – Open Terrain(1)Forming Part of Clause 9.6.1.3.(2)(b)
Type of GlassMaximum Glass Area, m2
Glass Thickness, mm
2.5345681012
Annealed0.460.751.161.602.253.765.328.70
Factory-sealed insulated glass (IG) units(2)0.801.342.112.934.106.909.6612.53
Heat-strengthened0.981.742.332.863.595.006.268.78
Tempered1.251.742.332.863.595.006.268.78
Wired0.220.360.550.761.051.752.474.09

Notes to Table 9.6.1.3.-D:

(1)
The maximum hourly wind pressure with one chance in fifty of being exceeded in any one year, as provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”
(2)
Maximum glass area values apply to IG units of two identical lites (annealed, heat-strengthened or tempered) spaced at 12.7 mm.
Table 9.6.1.3.-E Maximum Glass Area for Windows in Areas for which the 1-in-50 Hourly Wind Pressure (HWP) is Less than 0.75 kPa – Open Terrain(1)Forming Part of Clause 9.6.1.3.(2)(b)
Type of GlassMaximum Glass Area, m2
Glass Thickness, mm
2.5345681012
Annealed0.330.540.831.141.612.673.756.14
Factory-sealed insulated glass (IG) units(2)0.570.941.472.042.854.756.7210.97
Heat-strengthened0.701.151.792.443.064.365.347.47
Tempered1.061.481.992.443.064.365.347.47
Wired0.160.260.400.550.761.241.772.93

Notes to Table 9.6.1.3.-E:

(1)
The maximum hourly wind pressure with one chance in fifty of being exceeded in any one year, as provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”
(2)
Maximum glass area values apply to IG units of two identical lites (annealed, heat-strengthened or tempered) spaced at 12.7 mm.
Table 9.6.1.3.-F Maximum Glass Area for Windows in Areas for which the 1-in-50 Hourly Wind Pressure (HWP) is Less than 1.00 kPa – Open Terrain(1)Forming Part of Clause 9.6.1.3.(2)(b)
Type of GlassMaximum Glass Area, m2
Glass Thickness, mm
2.5345681012
Annealed0.250.400.620.841.171.942.754.50
Factory-sealed insulated glass (IG) units(2)0.420.681.041.462.053.414.877.92
Heat-strengthened0.510.841.301.792.523.694.606.44
Tempered0.921.281.722.102.633.694.606.44
Wired0.120.200.300.410.570.941.312.18

Notes to Table 9.6.1.3.-F:

(1)
The maximum hourly wind pressure with one chance in fifty of being exceeded in any one year, as provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”
(2)
Maximum glass area values apply to IG units of two identical lites (annealed, heat-strengthened or tempered) spaced at 12.7 mm.
Table 9.6.1.3.-G Glass Area for DoorsForming Part of Sentence 9.6.1.3.(3)
Glass Thickness, mmMaximum Glass Area, m2(1)
Type of Glass
AnnealedAnnealed, Multiple-Glazed, Factory-Sealed UnitsLaminatedWiredHeat-StrengthenedFully TemperedFully Tempered, Multiple-Glazed, Factory-Sealed
30.500.70(2)(2)1.001.002.00
41.001.50(2)(2)1.504.004.00
51.501.50(2)(2)1.50No limitNo limit
61.501.501.201.001.50No limitNo limit

Notes to Table 9.6.1.3.-G:

(1)
See Note A-Table 9.6.1.3.-G.
(2)
Not generally available.

9.6.1.4. Types of Glass and Protection of Glass
Add bookmark

(1)Glass sidelights greater than 500 mm wide that could be mistaken for doors, glass in storm doors and glass in sliding doors within or at every entrance to a dwelling unit and in public areas shall be

(a)safety glazing of the tempered or laminated type conforming to CAN/CGSB-12.1, “Safety Glazing,” or

(b)wired glass conforming to CAN/CGSB-12.11-M, “Wired Safety Glass.”

(2)Except as provided in Sentence (4), glass in entrance doors to dwelling units and in public areas, other than the entrance doors described in Sentence (1), shall be safety glazing or wired glass of the type described in Sentence (1) where the glass area exceeds 0.5 m2 and extends to less than 900 mm from the bottom of the door.

(3)Except as provided in Sentence (4), transparent panels that could be mistaken as a means of egress shall be protected by barriers or railings.

(4)Sliding glass partitions that separate a public corridor from an adjacent occupancy and that are open during normal working hours need not conform to Sentences (2), (3) and (5), except that such partitions shall be suitably marked to indicate their existence and position.

(5)Except as provided in Sentence (4), every glass or transparent door accessible to the public shall be equipped with hardware, bars or other permanent fixtures designed so that the existence and position of such doors is readily apparent.

(6)Glazing used for a shower or bathtub enclosure shall conform to Class A of CAN/CGSB-12.1, “Safety Glazing.”

Section 9.7. Windows, Doors and Skylights
Add bookmark

9.7.1. General
Add bookmark

9.7.1.1. Application
Add bookmark

(1)This Section applies to

(a)windows, doors and skylights separating conditioned space from unconditioned space or the exterior, and

(b)main entrance doors.

(2)For the purpose of this Section, the term “skylight” refers to unit skylights, roof windows and tubular daylighting devices.

(3)For the purpose of this Section, the term “doors” includes glazing in doors and sidelights for doors.

9.7.2. Required Windows, Doors and Skylights
Add bookmark

9.7.2.1. Entrance Doors
Add bookmark

(1)A door shall be provided at each entrance to a dwelling unit.

(2)Main entrance doors to dwelling units shall be provided with

(a)a door viewer or transparent glazing in the door, or

(b)a sidelight.

9.7.2.2. Other Requirements for Windows, Doors and Skylights
Add bookmark

(1)Minimum sizes of doorways and doors within a barrier-free path of travel shall conform to Section 9.5.

(2)The protection of window and door openings to protect persons from falling through them shall conform to Article 9.8.8.1.

(3)Properties of windows and doors within exits shall conform to Section 9.9.

(4)Windows and doors installed to provide the required means of egress from bedrooms shall conform to Subsection 9.9.10.

(5)The location and protection of windows, doors and skylights in order to control the spread of fire shall conform to Subsection 9.10.12.

(6)Doors between dwelling units and attached garages shall conform to Article 9.10.13.15.

(7)The surface flame-spread rating for doors and skylights shall conform to Article 9.10.17.1.

(8)Windows and doors installed to provide the required access to a building for firefighting purposes shall conform to Subsection 9.10.20.

(9)Windows and skylights installed to provide required non-heating season ventilation shall conform to Article 9.32.2.2.

9.7.2.3. Minimum Window Areas
Add bookmark

(1)Except as required in Article 9.9.10.1. and Sentence (3), the minimum window glass areas for rooms in buildings of residential occupancy or rooms that are used for sleeping shall conform to Table 9.7.2.3.

(2)The unobstructed glass area of a door or skylight is considered equivalent to that of a window.

(3)Work areas in live/work units shall conform to Clause 3.7.2.1.(2)(a).

(4)Where rooms with different requirements for window glass area are combined as described in Sentence 9.5.1.4.(1), the more restrictive requirement shall govern.

Table 9.7.2.3. Glass Areas for Rooms of Residential OccupancyForming Part of Sentence 9.7.2.3.(1)
LocationMinimum Unobstructed Glass Area With No Electric LightingMinimum Unobstructed Glass Area With Electric Lighting
Laundry, basement recreation room, unfinished basement4% of area servedWindows not required
Water-closet room0.37 m²Windows not required
Kitchen, kitchen space, kitchen alcove10% of area servedWindows not required
Living rooms and dining rooms10% of area served10% of area served
Bedrooms and other finished rooms not mentioned above5% of area served(1)5% of area served(1)

Notes to Table 9.7.2.3.:

9.7.3. Performance of Windows, Doors and Skylights
Add bookmark

9.7.3.1. General Performance Criteria
Add bookmark

(1)Except as provided in Sentences (2) to (4), windows, doors and skylights and their components separating conditioned space from unconditioned space or the exterior shall be designed, constructed and installed so that, when in the closed position, they

(a)resist the ingress of precipitation into interior space, (See Note A-9.7.4.2.(1))

(b)resist wind loads,

(c)control air leakage,

(d)resist the ingress of insects and vermin,

(e)where required, resist forced entry, and

(f)are easily operable when not intended to be fixed.

(2)Skylights and their components shall be designed, constructed and installed so that, when in the closed position, they resist snow loads.

(3)Main entrance doors and their components shall be designed, constructed and installed so that, when in the closed position, they

(a)control air leakage,

(b)resist the ingress of insects and vermin,

(c)resist forced entry, and

(d)are easily operable.

(4)Storm doors, sliding doors and their components shall be designed, constructed and installed so that, when in the closed position, they

(a)resist wind loads,

(b)control air leakage to a minimum allowable 5 m3h/m and a maximum allowable 8.35 m3h/m,

(c)resist the ingress of insects and vermin, and

(d)are easily operable.

(5)Compliance with the performance requirements described in Sentences (1) to (4) shall be demonstrated by

(a)complying with the requirements in

(i)Subsection 9.7.4. or 9.7.5., and

(ii)Subsection 9.7.6., or

(b)design and construction conforming to Part 5.

9.7.3.2. Heat Transfer Performance
Add bookmark

(1)Windows, doors and skylights described in Clause 9.7.1.1.(1)(a) and their components shall be designed, constructed and installed to

(a)minimize surface condensation on the warm side of the component, and (See Note A-9.7.3.2.(1)(a))

(b)ensure comfortable conditions for occupants.

(2)Compliance with the heat transfer performance requirements described in Sentence (1) shall be demonstrated by

(a)complying with the requirements in Article 9.7.3.3., or

(b)design and construction conforming to Part 5.

9.7.3.3. Thermal Characteristics of Windows, Doors and Skylights
Add bookmark

(1)Metal frames and sash of windows, doors and skylights shall incorporate a thermal break.

(2)Windows and doors described in Sentence (1) do not require a thermal break where they are installed as

(a)vehicular access doors,

(b)storm windows and doors, or

(c)windows and doors that are required to have a fire-resistance rating.

(3)Windows, doors and skylights with or without storm doors or sash that are installed in buildings where the intended use of the interior space will not result in high moisture generation shall have a maximum thermal transmittance (U-value) or minimum temperature index (I) in accordance with Table 9.7.3.3.

(4)Windows, doors and skylights, with or without storm doors or sash that are installed in portions of buildings where the intended use of the interior space will result in high moisture generation shall be designed in conformance with Subsection 5.3. (See Note A-9.25.5.2.)

Table 9.7.3.3. Maximum U-value or Minimum Temperature Index (I) for Windows, Doors and Skylights(1)(2)(3)Forming Part of Sentence 9.7.3.3.(3)
Component2.5% January Design Temperature
Between -15°C and -30°CColder than -30°C
max. U-value, W/m2Kmin. Imax. U-value, W/m2Kmin. I
Windows and Doors2.0681.777
Skylights3.0(2)2.7(2)

Notes to Table 9.7.3.3.:

(1)
U-values for specific products can be determined according to measures referenced in AAMA/WDMA/CSA 101/I.S.2/A440, “NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights.” Temperature index (I) is determined according to the physical test procedure given in CSA A440.2/A440.3, “Fenestration energy performance/User guide to CSA A440.2-19, Fenestration energy performance.”
(2)
There is no appropriate test procedure available for testing the condensation resistance of sloped glazing.
(3)
Where the U-value in this Table differs from the U-value provided in MMA Supplementary Standard SB-10, “Energy Efficiency Requirements” or MMA Supplementary Standard SB-12, “Energy Efficiency for Housing”, the most restrictive U-value shall apply.

9.7.4. Manufactured Windows, Doors and Skylights
Add bookmark

9.7.4.1. Application
Add bookmark

(1)This Subsection applies to windows, doors and skylights covered in the scope of AAMA/WDMA/CSA 101/I.S.2/A440, “North American Fenestration Standard/Specification for windows, doors, and skylights” (Harmonized Standard).

9.7.4.2. General
Add bookmark

(1)Manufactured and pre-assembled windows, doors and skylights and their installation shall conform to

(a)AAMA/WDMA/CSA 101/I.S.2/A440, “North American Fenestration Standard/Specification for windows, doors, and skylights” (Harmonized Standard),

(b)CSA A440S1, “Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration Standard/Specification for windows, doors, and skylights,”

(c)the remainder of this Subsection, and

(d)the applicable requirements in Subsection 9.7.6.

(See Note A-9.7.4.2.(1))

9.7.4.3. Performance Requirements
Add bookmark

(1)Performance grades for windows, doors and skylights shall be selected according to CSA A440S1, “Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration Standard/Specification for windows, doors, and skylights” so as to be appropriate for the conditions and geographic location in which the window, door or skylight will be installed.

(2)Windows, doors and skylights shall conform to the performance grades selected under Sentence (1) when tested in accordance with AAMA/WDMA/CSA 101/I.S.2/A440, “North American Fenestration Standard/Specification for windows, doors, and skylights” (Harmonized Standard).

(3)The minimum level of performance required for windows, doors and skylights shall be that of the Performance Class R.

(4)Exterior wood doors shall conform to CAN/CSA-O132.2 Series, “Wood Flush Doors,” and shall have legibly indicated on them

(a)the name of the manufacturer,

(b)the standard to which they were produced, and

(c)that they are of an exterior type.

9.7.5. Site-Built Windows, Doors and Skylights
Add bookmark

9.7.5.1. Application and Compliance
Add bookmark

(1)Materials, design, construction and installation of windows, doors and skylights that separate conditioned space from unconditioned space or the exterior but that are not within the scope of AAMA/WDMA/CSA 101/I.S.2/A440, “North American Fenestration Standard/Specification for windows, doors, and skylights,” shall conform

(a)to

(i)the remainder of this Subsection or Subsection 9.7.4., and

(ii)the applicable requirements in Subsection 9.7.6., or

(b)to Part 5.

(2)Glass for site-built windows, doors, sidelights for doors, and skylights shall comply with Section 9.6.

9.7.5.2. Resistance to Forced Entry for Doors
Add bookmark

(1)Except for exterior doors to garages and to other ancillary spaces, this Article applies to

(a)swinging entrance doors to dwelling units,

(b)swinging doors between dwelling units and attached garages or other ancillary spaces, and

(c)swinging doors that provide access directly or indirectly from a storage garage to a dwelling unit.

(See Note A-9.7.5.2.(1))

(2)Doors, frames and hardware that conform to a security level of at least Grade 10 as described in the Annex to ASTM F476, “Standard Test Methods for Security of Swinging Door Assemblies,” are not required to conform to Sentences (3) to (7). (See Note A-9.7.5.2.(2))

(3)Except as permitted in Sentence (2), wood doors as described in Sentence (1) shall

(a)be solid core or stile-and-rail type,

(b)be not less than 45 mm thick, and

(c)if of the stile-and-rail type, have a panel thickness of not less than 19 mm, with a total panel area not more than half of the door area.

(4)Except as permitted in Sentence (2), doors described in Sentence (1) shall be provided with

(a)a deadbolt lock with a cylinder having no fewer than 5 pins, and

(b)a bolt throw not less than 25 mm long, protected with a solid or hardened free-turning ring or beveled cylinder housing. (See Article 9.9.6.7.)

(5)Except as permitted in Sentence (2), an inactive leaf in double doors used in locations specified in Sentence (1) shall be provided with heavy-duty bolts top and bottom having an engagement of not less than 15 mm.

(6)Except as permitted in Sentence (2), hinges for doors described in Sentence (1) shall be fastened

(a)to wood doors with wood screws not less than 25 mm long and to wood frames with wood screws such that at least 2 screws per hinge penetrate not less than 30 mm into solid wood, or

(b)to metal doors and metal frames with machine screws not smaller than No. 10 and not less than 10 mm long.

(See Note A-9.7.5.2.(6))

(7)Strikeplates for deadbolts described in Sentence (4) shall be fastened

(a)to wood frames with wood screws that penetrate not less than 30 mm into solid wood, or

(b)to metal frames with machine screws not smaller than No. 8 and not less than 10 mm long.

(See Note A-9.7.5.2.(6))

(8)Except for storm doors or screen doors, doors described in Sentence (1) that swing outward shall be provided with hinges or pins so that the doors cannot be removed when they are in the closed position. (See Note A-9.7.5.2.(8))

(9)Solid blocking shall be provided on both sides at the lock height between the jambs for doors described in Sentence (1) and the structural framing so that the jambs will resist spreading by force.

Loading more of this Part…