Division B
Section 9.30. Flooring
Section 9.30. Flooring Copy linkAdd bookmark
9.30.1. General Copy linkAdd bookmark
9.30.1.1. Required Finished Flooring Copy linkAdd bookmark
(1)Finished flooring shall be provided in all residential occupancies.
9.30.1.2. Water Resistance Copy linkAdd bookmark
(1)Finished flooring in bathrooms, kitchens, public entrance halls, laundry and general storage areas shall consist of resilient flooring, felted-synthetic-fibre floor coverings, concrete, terrazzo, ceramic tile, mastic or other types of flooring providing similar degrees of water resistance. (See Note A-9.30.1.2.(1))
9.30.1.3. Sleepers Copy linkAdd bookmark
(1)Wood sleepers supporting finished flooring over a concrete base supported on the ground shall be not less than 19 mm by 38 mm and shall be treated with a wood preservative.
9.30.1.4. Finish Quality Copy linkAdd bookmark
(1)Finished flooring shall have a surface that is smooth, even and free from roughness or open defects.
9.30.2. Panel-Type Underlay Copy linkAdd bookmark
9.30.2.1. Required Underlay Copy linkAdd bookmark
(1)A panel-type underlay shall be provided under resilient flooring, parquet flooring, ceramic tile, felted-synthetic-fibre floor coverings or carpeting laid over lumber subflooring. (See Sentence 9.30.3.2.(1))
(2)Panel-type underlay shall be provided under resilient flooring, parquet flooring, felted-synthetic-fibre floor coverings or carpeting on panel-type subflooring whose edges are unsupported. (See Article 9.23.15.3.)
(3)Panel-type underlay shall be provided under ceramic tile applied with adhesive.
(4)Panel-type underlay shall be provided under resilient flooring on waferboard or strandboard subflooring.
9.30.2.2. Materials and Thickness Copy linkAdd bookmark
(1)Panel-type underlay shall be not less than 6 mm thick and shall conform to
(a)ANSI A208.1, “Particleboard,”
(b)CAN/CGSB-11.3-M, “Hardboard,”
(c)ANSI/HPVA HP-1, “American National Standard for Hardwood and Decorative Plywood,”
(d)CSA O121, “Douglas fir plywood,”
(e)CSA O151, “Canadian softwood plywood,”
(f)CSA O153, “Poplar plywood,” or
(g)CSA O437.0, “OSB and Waferboard.”
9.30.2.3. Fastening Copy linkAdd bookmark
(1)Panel-type underlay shall be fastened to the subfloor with staples, annular grooved flooring nails or spiral nails, spaced not more than 150 mm o.c. along the edges and 200 mm o.c. both ways at other locations.
(2)Nails for panel-type underlay shall be not less than 19 mm long for 6 mm thick underlay and 22 mm long for 7.9 mm thick underlay.
(3)Staples for panel-type underlay shall
(a)have not less than a 1.2 mm shank diameter or thickness with a 4.7 mm crown, and
(b)be not less than
(i)22 mm long for 6 mm underlay, and
(ii)28 mm long for 7.9 mm and 9.5 mm underlay.
9.30.2.4. Joints Offset Copy linkAdd bookmark
(1)Where panel-type underlay is required to be installed over plywood, OSB or waferboard, the joints in the underlay shall be offset not less than 200 mm from the joints in the underlying subfloor.
9.30.2.5. Surface Defects Copy linkAdd bookmark
(1)Underlay beneath resilient or ceramic floors applied with an adhesive shall have all holes or open defects on the surface patched so that the defects will not be transmitted to the finished surface.
9.30.3. Wood Strip Flooring Copy linkAdd bookmark
9.30.3.1. Thickness Copy linkAdd bookmark
(1)The thickness of wood strip flooring shall conform to Table 9.30.3.1.
| Type of Flooring | Maximum Joist Spacing, mm | Minimum Thickness of Flooring, mm | |
|---|---|---|---|
| With Subfloor | No Subfloor | ||
| Matched hardwood (interior use only) | 400 | 7.9 | 19.0 |
| 600 | 7.9 | 33.3 | |
| Matched softwood (interior or exterior use) | 400 | 19.0 | 19.0 |
| 600 | 19.0 | 31.7 | |
| Square edge softwood (exterior use only) | 400 | — | 25.4 |
| 600 | — | 38.1 | |
9.30.3.2. Strip Direction and End Joints Copy linkAdd bookmark
(1)Wood strip flooring shall not be laid parallel to lumber subflooring unless a separate underlay is provided.
(2)If wood strip flooring is applied without a subfloor, it shall be laid at right angles to the joists so that the end joints are staggered and occur over supports or are end matched.
(3)If the flooring is end matched, it shall be laid so that no 2 adjoining strips break joints in the same space between supports and each strip bears on no fewer than 2 supports.
9.30.3.3. Nailing Copy linkAdd bookmark
(1)When nails are used, wood strip flooring shall be toe nailed or face nailed with not less than one nail per strip at the spacings shown in Table 9.30.3.3., except that face nailed strips of more than 25 mm in width shall have at least 2 nails per strip.
(2)Face nails shall be countersunk.
| Finish Floor Thickness, mm | Minimum Length of Flooring Nails, mm | Maximum Spacing of Flooring Nails, mm |
|---|---|---|
| 7.9 | 38(1) | 200 |
| 11.1 | 51 | 300 |
| 19.0 | 57 | 400 |
| 25.4 | 63 | 400 |
| 31.7 | 70 | 600 |
| 38.1 | 83 | 600 |
Notes to Table 9.30.3.3.:
9.30.3.4. Staples Copy linkAdd bookmark
(1)Staples are permitted to be used to fasten wood strip flooring not more than 7.9 mm in thickness and not more than 50 mm in width provided the staples
(a)are not less than 29 mm long,
(b)have a shank diameter of not less than 1.19 mm,
(c)have a crown of not less than 4.7 mm, and
(d)are spaced not more than 400 mm o.c.
(2)Staples are permitted to be used to fasten wood strip flooring not more than 19 mm in thickness and not more than 83 mm in width provided the staples
(a)are not less than 51 mm long,
(b)have a shank diameter of not less than 1.82 mm,
(c)have a crown of not less than 12.7 mm, and
(d)are spaced not more than 400 mm o.c.
9.30.4. Parquet Flooring Copy linkAdd bookmark
9.30.4.1. Adhesive Copy linkAdd bookmark
(1)Adhesive used to attach parquet block flooring shall be suitable for bonding wood to the applicable subfloor material.
9.30.5. Resilient Flooring Copy linkAdd bookmark
9.30.5.1. Materials Copy linkAdd bookmark
(1)Resilient flooring used on concrete slabs supported on ground shall consist of asphalt, rubber, unbacked vinyl or vinyl with an inorganic type backing.
(2)Flooring described in Sentence (1) shall be attached to the base with a suitable waterproof and alkali-resistant adhesive.
9.30.6. Ceramic Tile Copy linkAdd bookmark
9.30.6.1. Substrate Copy linkAdd bookmark
(1)Ceramic tile shall be set in a mortar bed or applied to a sound smooth base with a suitable adhesive.
(2)Panel-type subfloor to which ceramic tile is to be applied with adhesive shall have its edges supported according to Article 9.23.15.3.