2.1.1. Scope
Add bookmark

2.1.1.1. Scope
Add bookmark

(1)This Part is concerned with the fire, structural, heating, ventilating and air-conditioning performance of farm buildings, as well as processes and operations carried out therein that involve a risk of explosion, high flammability or related conditions that create a hazard to life safety. (See Note A-2.1.1.1.(1))

2.1.2. Application
Add bookmark

2.1.2.1. Application
Add bookmark

(1)Except as provided in Sentences (2) and (3), this Part applies to all farm buildings

(a)that are

(i)more than 600 m2 in building area or more than 3 storeys in building height used for major occupancies classified as Group G, Division 1, 2 or 3 agricultural occupancies, or

(ii)used for major occupancies classified as Group G, Division 4, agricultural occupancies with no human occupants, and

(b)described in Sentence 2.1.2.2.(1).

(2)Subsections 2.2.6. and 2.2.7. do not apply to Group G, Division 4 major occupancies.

(3)Farm buildings not described in Sentence (1) shall conform to the requirements of Article 2.1.2.3.

2.1.2.2. Classification of Buildings Containing Agricultural Occupancies (See Note A-3.1.2.)
Add bookmark

(1)Buildings or parts of buildings containing an agricultural occupancy that has an occupant load of not more than one person per 40 m2 shall be classified according to their major occupancy as belonging to Group G, Division 1, 2, 3 or 4.

(2)Buildings or parts of buildings containing an agricultural occupancy that has an occupant load of more than one person per 40 m2 shall be classified according to their major occupancy as belonging to one of the Groups and Divisions listed in Table 3.1.2.1. of Division B.

(3)For the purposes of Sentences (1) and (2), the occupant load shall be determined based on the floor area or the part of the floor area that contains the agricultural occupancy.

(4)A building intended for use by more than one major occupancy shall be classified according to all the major occupancies for which it is used or intended to be used.

2.1.2.3. Small Farm Buildings
Add bookmark

(1)Except as provided in Sentences (2) to (6), farm buildings not more than 3 storeys in building height and not more than 600 m² in building area used for major occupancies classified as Group G, Division 1, 2, or 3 agricultural occupancies shall conform to the requirements in the CCBFC NRCC 38732 “National Farm Building Code of Canada.”

(2)Articles 1.1.1.2. and 3.1.8.1. and Subsections 3.1.4. and 4.1.4. in the CCBFC NRCC 38732 “National Farm Building Code of Canada” do not apply to farm buildings.

(3)Except as provided in Sentence (4), in the CCBFC NRCC 38732 National Farm Building Code of Canada, references in Articles 1.1.1.3., 2.2.2.1., 2.2.2.2., 2.3.1.1., 2.3.2.1., 3.1.1.1., 3.1.1.2., 3.1.2.1. and 3.1.6.1. to the CCBFC NRCC 38726 “National Building Code of Canada,” are deemed to be references to Ontario Regulation 403/97 (Building Code), as it read on December 30, 2006.

(4)The climatic values required for the design of farm buildings shall be in conformance with the climatic values provided in MMAH Supplementary Standard SB-1, “Climatic and Seismic Data.”

(5)A farm building of low human occupancy having a building area not exceeding 600 m2 and not more than three storeys in building height is deemed to comply with the structural requirements of CCBFC NRCC 38732 “National Building Code of Canada,” if it is designed and constructed in conformance with MMAH Supplementary Standard SB-11, “Construction of Farm Buildings.”

(6)Where a floor area or portion of a floor area within a farm building is intended to contain a hazardous extraction operation involving cannabis, the floor area or portion of the floor area shall conform to the requirements of Article 2.2.8.9.

2.1.3. Definitions
Add bookmark

2.1.3.1. Defined Terms
Add bookmark

(1)Words that appear in italics are defined in Article 1.4.1.2. of Division A.

2.1.4. Classification of Farm Buildings by Major Occupancy (See Note A-3.1.2.)
Add bookmark

2.1.4.1. Classification
Add bookmark

(1)Every farm building or part of a farm building shall be classified according to its major occupancy as belonging to one of the Divisions of Group G described in Table 2.1.4.1. (See Note A-2.1.4.1.(1)) (See also Note A-2.2.8.3.)

Table 2.1.4.1. Classification of Agricultural Major OccupanciesForming Part of Sentence 2.1.4.1.(1)
GroupDivisionDescription of Agricultural Occupancies
G1High-hazard agricultural occupancies
G2Agricultural occupancies not elsewhere classified in Group G
G3Greenhouse agricultural occupancies
G4Agricultural occupancies with no human occupants